Assessment of small-diameter aortic mechanical prostheses: physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation.

نویسندگان

  • R H Marcus
  • R S Heinrich
  • J Bednarz
  • S Lupovitch
  • J Abruzzo
  • R Borok
  • B Vandenberg
  • R E Kerber
  • W Piccione
  • A P Yoganathan
  • R M Lang
چکیده

BACKGROUND Noninvasive assessment of functionally stenotic small-diameter aortic mechanical prostheses is complicated by theoretical constraints relating to the hemodynamic relevance of Doppler-derived transprosthetic gradients. To establish the utility of Doppler echocardiography for evaluation of these valves, 20-mm Medtronic Hall and 19-mm St Jude prostheses were studied in vitro and in vivo. METHODS AND RESULTS Relations between the orifice transprosthetic gradient (equivalent to Doppler), the downstream gradient in the zone of recovered pressure (equivalent to catheter), and fluid mechanical energy losses were examined in vitro. Pressure-flow relations across the 2 prostheses were evaluated by Doppler echocardiography in vivo. For both types of prosthesis in vitro, the orifice was higher than the downstream gradient (P<0.001), and fluid mechanical energy losses were as strongly correlated with orifice as with downstream pressure gradients (r2=0.99 for both). Orifice and downstream gradients were higher and fluid mechanical energy losses were larger for the St Jude than the Medtronic Hall valve (all P<0.001). Whereas estimated effective orifice areas for the 2 valves in vivo were not significantly different, model-independent dynamic analysis of pressure-flow relations revealed higher gradients for the St Jude than the Medtronic Hall valve at a given flow rate (P<0.05). CONCLUSIONS Even in the presence of significant pressure recovery, the Doppler-derived gradient across small-diameter aortic mechanical prostheses does have hemodynamic relevance insofar as it reflects myocardial energy expenditure. Small differences in function between stenotic aortic mechanical prostheses, undetectable by conventional orifice area estimations, can be identified by dynamic Doppler echocardiographic analysis of pressure-flow relations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new approach for the evaluation of the severity of coarctation of the aorta using Doppler velocity index and effective orifice area: in vitro validation and clinical implications.

Early detection and accurate estimation of COA severity are the most important predictors of successful long-term outcome. However, current clinical parameters used for the evaluation of the severity of COA have several limitations and are flow dependent. The objectives of this study are to evaluate the limitations of current existing parameters for the evaluation of the severity of coarctation...

متن کامل

Doppler Assessment of Prosthetic Valve Orifice Area

Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...

متن کامل

Progressive functional deterioration of bioprostheses assessed by Doppler ultrasonography.

Doppler echocardiography was used to study the function of bioprosthetic heart valves by noninvasive means in 32 patients aged 29 to 72 years at various postoperative intervals. There were 24 Ionescu-Shiley, four Hancock, and four Carpentier-Edwards prostheses, 19 in the aortic and 13 in the mitral position. Initial studies were performed at a mean of 2.3 years after implantation and were repea...

متن کامل

Doppler assessment of prosthetic valve orifice area. An in vitro study.

BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...

متن کامل

The challenge of assessing heart valve prostheses by Doppler echocardiography.

The assessment of prosthetic valve function remains challenging. Echocardiography has become the key diagnostic tool not only because of its noninvasive nature and wide availability but also because of limitations inherent in alternative diagnostic techniques. Invasive evaluation is limited particularly in mechanical valves that cannot be crossed with a catheter, and in patients with both aorti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 98 9  شماره 

صفحات  -

تاریخ انتشار 1998