Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

نویسندگان

  • Neil A. Switz
  • Michael V. D'Ambrosio
  • Daniel A. Fletcher
چکیده

The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Communication Behaviour of Farmers with the Agricultural Extension Agents Using Cell Phone: A Case of Bangladesh

The cell phone is one of the potential Information Communication Technologies (ICTs) in agricultural development especially in developing countries like Bangladesh. Thus, this paper deals with the farmers’ communication with the agricultural extension agents using mobile phone. The study was conducted in Mymensingh District in Bangladesh. Data were collected from a sample of 110 farmers while b...

متن کامل

The Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone

Introduction:  The  use  of  mobile  communication  systems  has  dramatically  increased  over  the  past  decade. Although many studies have been performed to determine the effect of radio frequency (RF) but  less attention has been paid to the possible biological impact of exposure to extremely low frequency  (ELF) components.   The objective of this study is two folds. One is to design the ...

متن کامل

Investigating the relationship between mobile phone harmful use and Internet addiction with emotional divorce of teachers in Kermanshah city

The purpose of this study was to investigate the relationship between mobile phone harmful use and internet addiction with the emotional divorce of female teachers in Kermanshah. The statistical population of this study included all married female teachers in Kermanshah city in 1969-97. Using multi-stage cluster sampling, 269 people were selected as sample based on Morgan's table. The questionn...

متن کامل

The Model of Structural Relationships of Cyber Aggression Based on Self-Control with the Mediation of Mobile Phone Addiction in Adolescents: A Descriptive Study

Background and Objectives: Increasingly, cyberbullying has become a common phenomenon eroding the social media environment. The present study was conducted with the aim of determining the structural relationship pattern of cyber aggression based on self-control with the mediation of mobile phone addiction in adolescents. Materials and Methods: In this descriptive study, the statistical populat...

متن کامل

EPHRAIM AND OTHERS NOVEL PORTABLE MICROSCOPY FOR SCHISTOSOMIASIS DIAGNOSIS Diagnosis of Schistosoma haematobium Infection with a Mobile Phone-Mounted Foldscope and a Reversed-Lens CellScope in Ghana

We evaluated two novel, portable microscopes and locally acquired, single-ply, paper towels as filter paper for the diagnosis of Schistosoma haematobium infection. The mobile phone-mounted Foldscope and reversed-lens CellScope had sensitivities of 55.9% and 67.6%, and specificities of 93.3% and 100.0%, respectively, compared with conventional light microscopy for diagnosing S. haematobium infec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014