A new lens for observing fundus with a noncontact wide-angle viewing system
نویسندگان
چکیده
Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following the application of viscoelastic material, the lens can be put on the cornea without using a contact lens fixation ring. The larger diameter and lightweight characteristics of the new lens contributed to the overall stabilization. The smooth surface of this lens was able to achieve an intraoperative view of good quality not only during vitrectomy but also during scleral buckling procedures.
منابع مشابه
Combined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery
BACKGROUND The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery. METHODS Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as interna...
متن کاملNew type of antidrying lens for vitreous surgery with a noncontact wide-angle viewing system
Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the more serious problems when using a noncontact type wide-angle viewing system. We developed an antidrying corneal contact lens for use with this type of viewing system. The lens has a very thin meniscus made of polymethyl methacrylate with a large outer diameter. Following application of the viscoelast...
متن کاملScleral buckling for primary rhegmatogenous retinal detachment using noncontact wide-angle viewing system with a cannula-based 25 G chandelier endoilluminator
PURPOSE To assess the outcome of scleral buckling surgery using a noncontact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment. METHODS Twenty-eight eyes of 28 patients underwent a modified scleral buckling surgery using a noncontact wide-angle viewing system combined with a 27-gauge optic fiber inserted into the sclera at the pars plana thr...
متن کاملCommercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
PURPOSE We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system. METHODS THREE VITREORETINAL SURGEONS EVALUATED FUNDUS VISIBILITY DURING VITRECTOMY ON THE IMAGES OF FIVE STUDY MATERIALS USED ON THE CORNEA: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas perme...
متن کاملScleral buckling with a noncontact wide-angle viewing system in the management of retinal detachment with undetected retinal break: a case report
A young patient who showed rhegmatogenous retinal detachment with preoperatively undetected retinal break was successfully treated by scleral buckling using a noncontact wide-angle viewing system.
متن کامل