A new method of measuring cardiac output in man using lithium dilution.

نویسندگان

  • R A Linton
  • D M Band
  • K M Haire
چکیده

We describe a new indicator dilution method of measuring cardiac output in man. A bolus injection of lithium chloride 0.6 mmol was given via a central venous catheter and arterial plasma [Li+] recorded using a specially developed sensor incorporating an Li(+)-selective electrode. Cardiac output was derived from the lithium dilution curve, with a correction for packed cell volume. Lithium dilution cardiac output (LiDCO) was compared with thermodilution cardiac output (TD) using 22 lithium sensors in nine patients. For each sensor, one LiDCO was measured immediately before and one immediately after three TD estimations and mean values of LiDCO and TD derived. The correlation coefficient, r, was 0.89; slope of the regression 0.84; y intercept 0.72; bias 0.3 (0.5) litre min-1 (mean (TD-LiDCO) (1 SD). LiDCO appeared to be a safe, simple and accurate technique which does not require insertion of a pulmonary artery catheter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.

A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...

متن کامل

Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.

OBJECTIVE Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN Prospective, observational study. SETTING Surgical intensive care unit. PATIENTS Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS ...

متن کامل

PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery.

BACKGROUND Cardiac output is often monitored after cardiac operations with a pulmonary artery catheter. A new method has been introduced that measures cardiac output by lithium dilution (LiDCO) and uses these data to calibrate a system (PulseCO) that calculates cardiac output continuously from the energy of the arterial pressure waveform. It is unknown whether PulseCO measurements are valid ear...

متن کامل

Measurement of Cardiac Output Using the Photoelectric Earpiece: a Comparison with Simultaneous Fick Measurements.

• Since the early studies by Hamilton, Werko, and Doyle, and their colleagues, a variety of indicator dilution techniques have been developed for measuring the cardiac output in man. The most widely accepted have been those requiring the use of the continuously recording cuvette densitometer." Numerous studies have appeared to demonstrate close correlation of values by the Hamilton and by the s...

متن کامل

An appraisal of the double indicator-dilution method for the estimation of mitral regurgitation in human subjects.

T HE shape of an indicator-dilution curve is determined by at least 4 variables: cardiac output, the volume between the injection site and the sampling site, the presence of a left-to-right intracardiac shunt, and the presence of valvular regurgitation.1-3 In the absence of an intracardiac shunt and valvular regurgitation, one can predict the downslope of the arterial dilution curve, using the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 1993