Volar plate position and flexor tendon rupture following distal radius fracture fixation.
نویسندگان
چکیده
PURPOSE To determine whether there were differences between plate position in patients who had postoperative flexor tendon ruptures following volar plate fixation of distal radius fractures and those who did not. METHODS Three blinded reviewers measured the volar plate prominence and position on the lateral radiographs of 8 patients treated for flexor tendon ruptures and 17 matched control patients without ruptures following distal radius fracture fixation. We graded plate prominence using the Soong grading system, and we measured the distances between the plate and both the volar critical line and the volar rim of the distal radius. RESULTS A higher Soong grade was associated with flexor tendon rupture. Patients with ruptures had plates that were more prominent volarly and more distal than matched controls without ruptures. Plate prominence projecting greater than 2.0 mm volar to the critical line had a sensitivity of 0.88, a specificity of 0.82, and positive and negative predictive values of 0.70 and 0.93, respectively, for tendon ruptures. Plate position distal to 3.0 mm from the volar rim had a sensitivity of 0.88, a specificity of 0.94, and positive and negative predictive values of 0.88 and 0.94, respectively, for tendon ruptures. CONCLUSIONS We identified plate positions associated with attritional flexor tendon rupture following distal radius fracture fixation with volar plates. To decrease rupture risk, we recommend considering elective hardware removal after union in symptomatic patients with plate prominence greater than 2.0 mm volar to the critical line or plate position within 3.0 mm of the volar rim. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic III.
منابع مشابه
Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.
Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...
متن کاملAnterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture
We describe the case of a patient with distal radius fracture who became unable to flex the distal interphalangeal joint of the index finger after internal fixation using a volar locking plate. There was palpable crepitus with active thumb motion, and wrist radiographs showed prominence of the volar plate at the watershed line. Therefore, our initial diagnosis was plate-induced closed rupture o...
متن کاملLate rupture of flexor pollicis longus tendon 10 years after volar buttress plate fixation of a distal radius fracture: a case report.
We report the case of a complete rupture of flexor pollicis longus tendon in a 30-year old-man 10 years after open reduction and internal fixation of a distal radius fracture with a volar buttress plate.
متن کاملRisk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study.
PURPOSE To identify risk factors for tendon attrition after volar locking plate fixation of distal radius fractures. METHODS We prospectively assessed attrition of the flexor pollicis longus tendon at volar plate removal in 127 hands in 126 patients. We also evaluated preoperative lateral wrist radiographs, sonographs, and crepitus with flexor pollicis longus tendon motion and compared the de...
متن کاملFlexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons
OBJECTIVE The senior author previously reported a case of rupture of the flexor policis longus tendon after volar plating of a distal radius fracture. We hypothesized that restoration of the pronator quadratus to its native position after plating might prevent this problem. METHODS The authors report a new case of irritation of the flexor policis longus 2.5 years after volar plating of a dist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of hand surgery
دوره 38 6 شماره
صفحات -
تاریخ انتشار 2013