One-Year Follow-Up of Patients Undergoing Transvenous Extraction of Pacemaker and Defibrillator Leads

نویسندگان

  • Maciej Kempa
  • Szymon Budrejko
  • Marta Piepiorka-Broniecka
  • Jan Rogowski
  • Dariusz Kozlowski
  • Grzegorz Raczak
  • Xianwu Cheng
چکیده

INTRODUCTION The number of pacemaker and ICD implantations has increased substantially in the recent years. Therefore, complications are also observed in a greater number. In many cases, transvenous extraction of the previously implanted device (pacemaker or ICD) is the only solution. One may find in the literature information about the efficacy and safety of that procedure, but data concerning the results of long-term follow up are still limited. AIM The aim of the study was to assess the one-year mortality in the cohort of patients undergoing transvenous lead extraction procedures in our centre. METHODS Records of the patients undergoing transvenous lead removal in the Department of Cardiology and Electrotherapy of the Medical University of Gdańsk were analyzed. We collected detailed information about 192 patients that had undergone the procedure from January 2003 until June 2012. Data were collected from medical and surgical records. We analyzed concomitant diseases, indications, and possible complications. Long-term follow-up data were gathered in the follow-up ambulatory records and over-the-phone interviews with patients or families. In several cases, we consulted the database of the Polish National Health Fund. RESULTS During the early post-operative period 5 patients died, although none of those deaths was associated with the procedure itself. No other major complications were observed. During one-year follow-up other 5 patients died, which gave the overall one-year survival rate of 92.7%. Heart failure, renal failure and an infective indication showed significant association with increased mortality. CONCLUSION Results of transvenous lead extraction, a relatively safe procedure, should be assessed over time extending beyond the sole perioperative period. Some complications may be delayed in their nature, and may be observed only during the long-term follow up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction

BACKGROUND AND OBJECTIVES The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extr...

متن کامل

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath.

With the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to the clinic with a pacemaker pocket infection. The atrial lead was an Accufix Bipolar J-Atrial activ...

متن کامل

Left superior vena cava persistence in patients undergoing pacemaker or cardioverter-defibrillator implantation: a 10-year experience.

OBJECTIVE The persistence of a left superior vena cava (LSVC) has been observed in 0.3% of the general population as established by autopsy. In the adult population, it is an important anatomic finding if a left superior approach to the heart is considered. The aim of the study was to evaluate the prevalence of a LSVC in patients undergoing pacemaker (PM) and cardioverter-defibrillator (CD) imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015