Laser in situ keratomileusis for hyperopia and hyperopic and mixed astigmatism with LADARVision using 7 to 10-mm ablation diameters.
نویسندگان
چکیده
PURPOSE To evaluate the results of laser in situ keratomileusis (LASIK) performed to correct hyperopia, and hyperopic and mixed astigmatism using wider ablation diameters (optical zone diameter and overall ablation diameter) than those commonly used with the same and other lasers. METHODS After flap creation using an Alcon SKBM microkeratome set for a 10-mm flap diameter, 53 eyes (33 patients) with a mean spheroequivalent attempted correction of +2.34 +/- 2.09 D underwent LASIK (Alcon LADARVision 4000) using a 7-mm optical zone diameter and a 3-mm transition zone for an overall 10-mm total ablation diameter. The nasal hinge was prevented from undesired ablation by the use of proprietary hinge protector software. Eyes were followed for 6 months after surgery. RESULTS Six months after surgery, mean spheical equivalent refractive error was -0.22 +/- 0.41 D. There were 79.2% of eyes within +/- 0.50 D, and 98.1% within +/- 1.00 D of intended correction. Uncorrected visual acuity of 20/20 or better was achieved by 28 eyes (53%) and 20/40 or better by 50 eyes (94.3%). No meaningful visual complaints during nighttime hours, such as haloes or glare, were subjectively reported by patients. CONCLUSION The use of larger ablation diameters in LASIK for hyperopia, and hyperopic and mixed astigmatism produced accurate results, early refractive stability, and good visual performance.
منابع مشابه
Top 5 pearls to consider when implanting advanced technology IOLs in patients with unusual circumstances.
The mainstay of treatment for those with hyperopic astigmatism who wish to bypass the need for glasses or contacts has traditionally been laser treatment. Both hyperopic laser in situ keratomileusis (LASIK) and photorefractive keratotomy (PRK) have been used to correct hyperopic astigmatism. Although LASIK can provide promising results for a portion of patients with hyperopic eyes, it becomes l...
متن کاملAssessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction
INTRODUCTION Laser vision correction for hyperopia is challenging. The purpose of the study was to assess the refractive outcomes of femtosecond-assisted laser in situ keratomileusis (LASIK) for hyperopic correction using wavefront-optimized ablation profiles. METHODS This retrospective case series study included 20 Egyptian patients (40 eyes) with hyperopia or hyperopic astigmatism with a me...
متن کاملExcimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.
The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many ...
متن کاملHyperopia and hyperopic astigmatism correction with the SCHWIND ESIRIS: 1-year results
surgery has opened up the possibility to change the corneal curvature to compensate for refractive errors of the eye. In the case of small spot hyperopic laser in situ keratomileusis (H–LASIK), excimer laser systems produce a steepness of the cornea by ablating mainly at the periphery of the cornea. Hyperopic laser in situ keratomileusis (H-LASIK) treatments induce aberrations1. Other studies2,...
متن کاملTopography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform
BACKGROUND The purpose of this study was to evaluate the safety and efficacy of topography-guided ablation using the WaveLight 400 Hz excimer laser in laser-assisted in situ keratomileusis (LASIK) for hyperopia and/or hyperopic astigmatism. METHODS We prospectively evaluated 208 consecutive LASIK cases for hyperopia with or without astigmatism using the topography-guided platform of the 400 H...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 19 5 شماره
صفحات -
تاریخ انتشار 2003