A new method for the absolute radiance calibration for UV–vis measurements of scattered sunlight
نویسندگان
چکیده
Absolute radiometric calibrations are important for measurements of the atmospheric spectral radiance. Such measurements can be used to determine actinic fluxes, the properties of aerosols and clouds, and the shortwave energy budget. Conventional calibration methods in the laboratory are based on calibrated light sources and reflectors and are expensive, time consuming and subject to relatively large uncertainties. Also, the calibrated instruments might change during transport from the laboratory to the measurement sites. Here we present a new calibration method for UV–vis instruments that measure the spectrally resolved sky radiance, for example zenith sky differential optical absorption spectroscopy (DOAS) instruments or multi-axis (MAX)DOAS instruments. Our method is based on the comparison of the solar zenith angle dependence of the measured zenith sky radiance with radiative transfer simulations. For the application of our method, clear-sky measurements during periods with almost constant aerosol optical depth are needed. The radiative transfer simulations have to take polarisation into account. We show that the calibration results are almost independent from the knowledge of the aerosol optical properties and surface albedo, which causes a rather small uncertainty of about < 7 %. For wavelengths below about 330 nm it is essential that the ozone column density during the measurements be constant and known.
منابع مشابه
UV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملA Fabry–Perot interferometer-based camera for two-dimensional mapping of SO2 distributions
We examine a new imaging method for the remote sensing of volcanic gases, which relies on the regularly spaced narrow-band absorption structures in the UV– VIS of many molecules. A Fabry–Perot interferometer (FPI) is used to compare the scattered sunlight radiance at wavelengths corresponding to absorption bands with the radiance at wavelengths in between the bands, thereby identifying and quan...
متن کاملStratospheric Aerosol Retrieval From OSIRIS Limb Scattered Sunlight Spectra
The recent development of satellite observations of limb scattered sunlight at optical wavelengths has afforded a new opportunity to measure the vertical structure of atmospheric composition from the upper troposphere to the mesosphere, on a global scale. The determination of profiles of atmospheric composition from observed limb radiance profiles requires two elements, a forward radiative tran...
متن کاملVicarious satellite calibration in the solar spectral range by means of calculated radiances and its application to Meteosat.
The method of vicarious calibration by means of calculated radiances allows absolute calibration of satellite radiometers in orbit. It works by comparing counts from the radiometer to be calibrated with corresponding absolute radiances, calculated from actual values of the relevant optically acting parameters of the atmosphere and the earth's surface. The method is applied to the VIS-channel (i...
متن کامل