Ophthalmic micro-operating chair.
نویسنده
چکیده
The proper performance of micro-manipulative techniques depends upon three main factors: a good viexv of the procedure; properly designed tools wvhich can be held in the hand yet have accurate and efficient working ends; a relaxed position so that the operator avoids spending energy fighting against gravity. Mluch thought and experience is being displayed in the introduction of microscopes and instruments for opthalmic micro-surgery (and the acquisition of the complete outfit is very costly, so that equipment must be accumulated gradually). The surgeon's seat is out of sight and mind, unless it is uncomfortable or unsuitable, but is an essential part of the equipment, in that it 'K _ y enables relaxed control of all stages of the operation. The present stool, which has been designed to fit in wvith the standard British operating table used for general and specialist surgery, enables the operator to work with the operating microscope. The simple hydraulic valve regulates the height under the weight of the surgeon to cover a wide combination of tables or
منابع مشابه
A Simple Way to Achieve the Routine Position for Phacoemulsification in a Patient with Marked Thoracic Kyphosis
PURPOSE To introduce a simple way for achieving the routine position for phacoemulsification in a patient with a marked thoracic kyphosis. CASE REPORT A 74-year-old man with marked thoracic kyphosis and visually significant cataracts presented for surgery; he was unable to lie flat due to the severe deformity. The best possible surgical position was achieved by placing a chair with an adjusta...
متن کاملHead support for the patient during ophthalmic microsurgery.
The increasing use of the binocular operating microscope in ophthalmic surgery has highlighted both the desirability of some form of support for the operating surgeon's arms and the need for better fixation of the patient's head. Arm rests attached to the operating chair (Barraquer and Boberg-Ans, I959) or to the operating table (Pierse, I969) have been described. A more sophisticated mobile ar...
متن کاملRemoval of a giant nonmagnetic intraocular foreign body using micro alligator forceps.
PURPOSE To introduce a new method for removal of a giant nonmagnetic intraocular foreign body using micro alligator forceps. PATIENTS AND METHODS Eleven patients underwent pars plana vitrectomy and lensectomy. The micro alligator forceps were used to grasp and extract the giant nonmagnetic intraocular foreign body through a sclerocorneal tunnel. RESULTS All patients underwent surgical remov...
متن کاملDetermining variability of ophthalmic arterial Doppler signals using Lyapunov exponents
The new method presented in this study was directly based on the consideration that ophthalmic arterial Doppler signals are chaotic signals. This consideration was tested successfully using the nonlinear dynamics tools, like the computation of Lyapunov exponents. Multilayer perceptron neural network (MLPNN) architecture was formulated and used as a basis for determining variabilities such as st...
متن کاملDesign and Development of a Persian Office Chair Satisfaction Questionnaire
Background and Objectives: Accurate measurement of the employees’ satisfaction with their office chairs can provide valid feedback on the chair design quality for the manufacturers and researchers. This study aims to design a valid and psychometrically evaluated questionnaire for measuring satisfaction with office chairs. Methods: Through studying the two main documents about chair ergonomics ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 57 10 شماره
صفحات -
تاریخ انتشار 1973