Assessment of geometric and mechanical parameters in wheelchair seating: a variability study.

نویسندگان

  • C Maltais
  • J Dansereau
  • R Aissaoui
  • M Lacoste
چکیده

A measurement method has been developed to quantify the posture of able-bodied subjects seated in their wheelchair. Fourteen geometric parameters were measured in order to represent the pelvis, trunk and lower limbs orientations. They were defined by digitizing the three-dimensional (3-D) position of 23 anatomical landmarks using a mechanical articulated arm (Microscribe3D, Immersion Corporation). Mechanical parameters were used to measure the maximum pressure, mean pressure and peak pressure gradient on the seat and the back of the wheelchair using a force sensing array (Vista Medical, Inc.). A third set of parameters combining mechanical and geometric measurements were defined to represent pelvic tilt and ischial pressure orientations. However, different types of errors are associated to the measurement of these geometric and mechanical parameters. The purpose of this study was to evaluate these errors and their impact on the precision of the various parameters on a sample group of five able-bodied subjects. Results showed that variability of most of the geometric parameters is below 2 degrees with the sagittal rotation of the pelvis presenting the highest variability (3.8 degrees) and the thigh angle the lowest one (0.5 degrees). The variability of the mechanical parameters were respectively equal to 4.9% for the mean pressure, 9.3% for the peak pressure gradient and 16.9% for the maximum pressure under ischial tuberosities. It is suggested that the method proposed in this paper could be used as an accurate procedure to characterize the posture of subjects sitting in a wheelchair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive Needs Assessment Study and Deployment of QFD Targeted at New Wheelchair Design

Objectives: Extensive use of wheelchair increases caregiver dependency, risk of bedsores, risk of injury during transfer, and so on, and it effectively decreases quality of life, safety, and comfort of the people with disability. Therefore, improving the design of wheelchairs is highly essential in promoting the quality of life and level of participation among people with disability. The design...

متن کامل

The effect of rear-wheel position on seating ergonomics and mobility efficiency in wheelchair users with spinal cord injuries: a pilot study.

This study analyzed the effect of rear-wheel position on seating comfort and mobility efficiency. Twelve randomly selected paraplegic wheelchair users participated in the study. Wheelchairs were tested in two rear-wheel positions while the users operated the wheelchair on a treadmill and while they worked on a computer. Propulsion efficiency, seating comfort, and propulsion qualities were regis...

متن کامل

Wheelchair Seating Assessment and Intervention: A Comparison Between Telerehabilitation and Face-to-Face Service

This study compared outcomes of wheelchair seating and positioning interventions provided by telerehabilitation (n=10) and face-to-face (n=20; 10 in each of two comparison groups, one urban and one rural). Comparison clients were matched to the telerehabilitation clients in age, diagnosis, and type of seating components received. Clients and referring therapists rated their satisfaction and ide...

متن کامل

مقایسه نیروهای وارد بر کمر در وظایف جابجایی دستی بیمار

Background: Patient Manual handling is one of the major risk factors in musculoskeletal disorders among healthcare workers (HCWs). Therefore, the purpose of this study was to estimate the mechanical force on the low back of the staff responsible for patient manual handling and to exam in the effect of patient manual handling by two people on the level forces exerted on HCWs ҆ low back. meth...

متن کامل

Metabolite Parameters as an Appropriate Alternative Approach for Assessment of Bioequivalence of Two Verapamil Formulations

A bioequivalence study of two verapamil formulations (generic verapamil tablets and Isoptin® tablets) was performed by comparing pharmacokinetic parameters of the parent drug and its major metabolite, norverapamil following a single dose administration of 80 mg verapamil hydrochloride in 22 healthy volunteers according to a randomized, two-period, crossover-design study. Moreover, the feasibili...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 1999