The relationship between the Trendelenburg position and cerebral hypoxia inpatients who have undergone robot-assisted hysterectomy and prostatectomy

نویسندگان

  • Ali Özgün
  • Asuman Sargın
  • Semra Karaman
  • İlkben Günüşen
  • Işık Alper
  • Fatma Zekiye Aşkar
چکیده

Background/aim: This study aimed to evaluate the relationship between the Trendelenburg position and cerebral hypoxia in robot-assisted hysterectomy and prostatectomy.Materials and methods: A standardized mini-mental state examination was administered to 50 patients enrolled in the study 1 h before and after surgery. Near infrared spectroscopy (NIRS) values and hemodynamic and respiratory parameters were recorded after induction of anesthesia (baseline) and once every 20 min in the Trendelenburg position and supine positions. The relationship between the development of cerebral desaturation and the patient's position was examined. Results: For all patients, the baseline mean cerebral oxygen saturation (RSO2) on the right and left were 70.5 ± 7.3% and 70.6 ± 6.7%, respectively. Right RSO2 values at 20 min and 60 min in the Trendelenburg position decreased significantly, but they increased at 120 min. A significant positive correlation was found between right RSO2 and EtCO2 in the supine period following surgery, and between left RSO2 and EtCO2 at 60 min in the Trendelenburg and supine positions. The relationship between NIRS values and cognitive dysfunction was not significant.Conclusion: We found that cerebral saturation decreases as age increases, and cerebral desaturation may occur owing to the Trendelenburg position. There was no correlation between patients? cognitive function and NIRS values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of 25- and 30-degree Trendelenburg positions on intraocular pressure changes during robot-assisted radical prostatectomy

Background The objective of this study was to assess the effects of 25-degree and 30-degree Trendelenburg positions on intraocular pressure (IOP) changes during robot-assisted radical prostatectomy (RARP). Materials and methods This prospective study involved a total of 30 consecutive patients undergoing RARP. All participants were randomly divided into two groups: Trendelenburg position with...

متن کامل

Dynamic Arterial Elastance in Predicting Arterial Pressure Increase After Fluid Challenge During Robot-Assisted Laparoscopic Prostatectomy

During robot-assisted laparoscopic prostatectomy, specific physiological conditions such as carbon dioxide insufflation and the steep Trendelenburg position can alter the cardiac workload and cerebral hemodynamics. Inadequate arterial blood pressure is associated with hypoperfusion, organ damage, and poor outcomes. Dynamic arterial elastance (Ea) has been proposed to be a useful index of fluid ...

متن کامل

Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position

BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...

متن کامل

Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial

BACKGROUND Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelen...

متن کامل

Mask Phenomenon Following Robot-assisted Prostatectomy: A Rare Complication due to Trendelenburg Position

Injuries caused by position during the perioperative period are one of the risk factors for anesthesia and surgery. However, the Trendelenburg position, which is especially used in robot-assisted urological surgeries, might cause unknown morbidities [1]. Trendelenburg position and pneumoperitoneum together with facial and upper respiratory tract edema might cause venous stasis in the head and n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Turkish journal of medical sciences

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2017