The use of a radiofrequency needle improves the safety and efficacy of transseptal puncture for atrial fibrillation ablation.

نویسندگان

  • Roger A Winkle
  • R Hardwin Mead
  • Gregory Engel
  • Rob A Patrawala
چکیده

BACKGROUND Atrial fibrillation (AF) ablation requires transseptal puncture to gain entry to the left atrium (LA). On rare occasions, LA entry cannot be achieved or cardiac perforation results in pericardial tamponade. OBJECTIVE This study sought to compare a new radiofrequency (RF) transseptal needle with the standard needle. METHODS We evaluated 1,550 AF ablations in 1,167 patients. We compared 975 transseptal punctures done using a standard needle to 575 done using a new electrode-tipped needle attached to an RF perforation generator. RESULTS The rate of failure to cross the atrial septum was lower for the RF needle (1 of 575 [0.17%] vs. 12 of 975 [1.23%], P = .039) and there were fewer pericardial tamponades with the RF needle (0 of 575 [0.00%] vs. 9 of 975 [0.92%], P = .031). Multivariate analysis showed the RF needle use was the only variable associated with a lower incidence of tamponade (P = .04). Becasuse the RF needle was used later in our series, we examined our 975 standard needle punctures over time for evidence of improved operator experience that might explain the superior RF results. For the standard needle, there was no trend for improved septal crossing rates (P = .794) or fewer tamponades (P = .456) with more operator experience. Instrumentation time was shorter for the RF needle (27.1 ± 10.9 vs. 36.4 ± 17.7 minutes, P < .0001). CONCLUSION Our data suggest that the RF needle is superior to the standard transseptal needle. It results in shorter instrumentation times, a greater efficacy in transseptal crossing, and fewer episodes of pericardial tamponade.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...

متن کامل

NRG™ RF powered transseptal needle: a useful technique for transcatheter atrial septostomy and Fontan fenestration: report of three cases.

Transseptal puncture (TSP) is a frequently performed procedure for gaining access to the left atrium for catheter ablation, hemodynamic assessment of the left heart, left ventricular assist device implantation, percutaneous left atrial appendage closure or mitral valvuloplasty during childhood and adulthood. The standard technique for transseptal puncture applies mechanical pressure on the foss...

متن کامل

Double transseptal puncture guided by real-time three-dimensional transoesophageal echocardiography during atrial fibrillation ablation.

A 65-year-old man was admitted to our centre because of recurrent drug-resistant episodes of paroxysmal atrial fibrillation, for pulmonary vein radiofrequency catheter ablation. Double transseptal (TS) puncture was performed under realtime three-dimensional transoesophageal echocardiography (RT 3D TEE) guidance. We started by placing a quadripolar catheter in the coronary sinus and a Pigtail ca...

متن کامل

ECG findings of acute myocardial infarction and atrioventricular block during a transseptal procedure for left atrial ablation.

We report on a patient with transient atrioventricular block and ST-segment elevation mimicking the ECG of myocardial infarction during transseptal puncture for radiofrequency catheter ablation of atrial fibrillation. Symptoms and EGG findings resolved spontaneously. A neurally-mediated mechanism, activated by the mechanical effects of the transseptal puncture on the interatrial septum and lead...

متن کامل

Double Transseptal Puncture for Catheter Ablation of Atrial Fibrillation: Safety of the Technique and Its Use in the Outpatient Setting

Introduction. For pulmonary vein isolation in patients with atrial fibrillation (AF), some centers use the double transseptal puncture technique for catheter access in order to facilitate catheter manipulation within the left atrium. However, no safety data has so far been published using this approach. Method. 269 ablation procedures were performed in 243 patients (mean age 56.6 ± 9.3 years, 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart rhythm

دوره 8 9  شماره 

صفحات  -

تاریخ انتشار 2011