Dependence of Chlorine Isotope Separation in Ion Exchange Chromatography on the Nature and Concentration of the Eluent
نویسندگان
چکیده
In a heterogeneous electrolyte system of a strongly basic anion exchanger and solutions of NaBF4 or NaClC>4 we established the influence of the nature and concentration of the eluent in chromatographic experiments on chlorine isotope separation. Results show that when the electrolyte concentration is increased the degree of isotope separation decreases. With NaBF4 the separation factor is greater than with NaC104 under conditions which are otherwise the same. For electrolyte solutions containing C I O 4 , N03~ and B F 4 there is a linear relation between the separation factor of the chlorine isotopes and the logarithm of the heat of anion hydration of the elution electrolyte.
منابع مشابه
Ion Exchange Column Performance Model for Separation of Zr(IV) and Hf(IV) in Elution Process
A mathematical model of sorption of Zirconium and Hafnium cations mixture and elution of these ions from a cation exchange resin bed is developed. Sulfuric acid is selected as the eluent for selective separation of Zr and Hf in a packed bed of Dowex cation exchange resin. The column model is a dispersed plug flow model,and assumed to consist of randomly packed synthetic and spherical resin ...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملImmunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography
Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...
متن کاملA MODEL STUDY OF LASER ISOTOPE SEPARATION BY PHOTOIONIZATION OR PHOTODISSOCIATION PROCESS
In this study, the selective photoexication of isotopic mixtures by laser light is investigated. Atomic and molecular methods are examined and rate equations are derived for both cases. Two and three step photoionization techniques are considered and rate equations are solved for ion yields. The molecular photodissociation process is also studied and the dependence of the dissociation produ...
متن کامل