Feasibility study of the use of frozen human sera in split-sample comparison of immunoassays with candidate reference measurement procedures for total thyroxine and total triiodothyronine measurements.

نویسندگان

  • Linda M Thienpont
  • Katleen Van Uytfanghe
  • John Marriott
  • Peter Stokes
  • Lothar Siekmann
  • Anja Kessler
  • David Bunk
  • Susan Tai
چکیده

BACKGROUND Diagnostic manufacturers must ensure/document metrologically traceable assays. We report on a feasibility study of a split-sample comparison for that purpose. Processed, frozen single-donation sera, assigned target values by candidate reference measurement procedures (cRMPs), were used with immunoassays for total thyroxine (TT(4)) and triiodothyronine (TT(3)) as models. METHODS Two serum panels were quantified for TT(4) and TT(3) with validated cRMPs and measured in parallel with at least 14 immunoassays. The results were interpreted in terms of traceability of calibration (trueness) and of the individual measurement result (accuracy) by linear regression analysis and graphical representation against specifications. The commutability of the sera was investigated by parallel analysis of TT(4) in freshly collected but nonfiltered specimens. RESULTS The TT(4) (TT(3)) concentrations in the sera (according to the cRMPs) were 64-269 nmol/L (0.88-13.7 nmol/L). The method comparison showed that for TT(4), on average, the immunoassays produced results in agreement with the cRMPs, whereas for TT(3), results were typically higher. It also demonstrated a considerable between-assay divergence in traceability of calibration and accuracy. The evidence of noncommutability of the sera attributable to processing, however, indicates that the interpretation should be treated with caution. CONCLUSIONS Frozen sera can be used for documenting/validating traceability of total thyroid measurements. The way in which the sera are processed may jeopardize commutability, however, and therefore requires in-depth investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metrologic traceability of total thyroxine measurements in human serum: efforts to establish a network of reference measurement laboratories.

BACKGROUND Assuring/demonstrating metrologic traceability of in vitro diagnostics necessitates the availability of measurand-specific reference measurement systems (RMSs) and the possibility for industry to work with competent reference measurement laboratories (RMLs). Here we report the results of a European project to investigate the feasibility of developing a RMS for serum total thyroxine. ...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

Evaluation of Total Antioxidant, Total Calcium, Selenium, Insulin, Free Triiodothyronine and Free Thyroxine Levels in Cows with Ketosis

Ketosis is an important metabolic disease of high milk-producing cows. There are significant changes in many metabolite and hormonal concentrations in metabolic diseases. This study was carried out to assess the concentrations calcium (Ca), selenium (Se), total antioxidant (TAOC), insulin, free triiodothyronine (fT3) and free thyroxine (fT4) in cows with subclinical and clinical ketosis. This s...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.

BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 12  شماره 

صفحات  -

تاریخ انتشار 2005