Implementation and Verification of a Nodally-Integrated Tetrahedral Element in FEBio

نویسندگان

  • Steve A. Maas
  • Benjamin J. Ellis
  • David S. Rawlins
  • Lowell T. Edgar
  • Corinne R. Henak
چکیده

Finite element simulations in computational biomechanics commonly require the discretization of extremely complicated geometries. Creating meshes for these complex geometries can be very difficult and time consuming using hexahedral elements. Automatic meshing algorithms exist for tetrahedral elements, but these elements often have numerical problems that discourage their use in complex finite element models. To overcome these problems we have implemented a stabilized, nodally-integrated tetrahedral element formulation in FEBio, our in-house developed finite element code, allowing researchers to use linear tetrahedral elements in their models and still obtain accurate solutions. In addition to facilitating automatic mesh generation, this also allows researchers to use mesh refinement algorithms which are fairly well developed for tetrahedral elements but not so much for hexahedral elements. In this document, the implementation of the stabilized, nodallyintegrated, tetrahedral element, named the “UT4 element”, is described. Two slightly different variations of the nodally integrated tetrahedral element are considered. In one variation the entire virtual work is stabilized and in the other one the stabilization is only applied to the isochoric part of the virtual work. The implementation of both formulations has been verified and the convergence behavior illustrated using the patch test and three verification problems. Also, a model from our laboratory with very complex geometry is discretized and analyzed using the UT4 element to show its utility for a problem from the biomechanics literature. The convergence behavior of the UT4 element does vary depending on problem, tetrahedral mesh structure and choice of formulation parameters, but the results from the verification problems should assure analysts that a converged solution using the UT4 element can be obtained that is more accurate than the solution from a classical linear tetrahedral formulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FEBio: finite elements for biomechanics.

In the field of computational biomechanics, investigators have primarily used commercial software that is neither geared toward biological applications nor sufficiently flexible to follow the latest developments in the field. This lack of a tailored software environment has hampered research progress, as well as dissemination of models and results. To address these issues, we developed the FEBi...

متن کامل

A Current-Mode Single-Resistance-Controlled Oscillator Employing VDCC and All Grounded Passive Elements

Realization of a novel single-resistance-controlled oscillator, employing an active element and all grounded passive elements, is the purpose of this manuscript. With requirements for completing the design being only a single Voltage Differencing Current Conveyor and four grounded passive components, it is also a preferable choice for integrated circuit implementation. The designed circuit has ...

متن کامل

Lagrangian finite element treatment of transient vibration/acoustics of biosolids immersed in fluids

Superposition principle is used to separate the incident acoustic wave from the scattered and radiated waves in a displacement-based finite element model. An absorbing boundary condition is applied to the perturbation part of the displacement. Linear constitutive equation allows for inhomogeneous, anisotropic materials, both fluids and solids. Displacement-based finite elements are used for all...

متن کامل

Comparison between FEBio and Abaqus for biphasic contact problems

Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of ...

متن کامل

A New Restructured Shaded Pole Induction Motor- 3D Finite Element Analysis and Experimental Verification

Shaded pole induction motors, despite the simplicity and low cost, are difficult to analyze particularly in the equivalent circuit methods, due to the asymmetric structure, saturation, harmonics, inaccurate estimation of leakage inductances and skew. Hence, 3D numerical methods could be very useful in the design and optimization stage. This paper presents the 3D transient finite element analysi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011