Background—Noninvasive cardiac evaluation is of great importance in transgenic mice. Transthoracic echocardiography can visualize the left ventricle well but has not been as successful for the right ventricle (RV). We developed a method of transesophageal echocardiography (TEE) to evaluate murine RV size and function. Methods and Results—Normoxic and chronically hypoxic mice (FIO250.11, 3 weeks) and agarose RV casts were scanned with a rotating 3.5F/30-MHz intravascular ultrasound probe. In vivo, the probe was inserted in the mouse esophagus and withdrawn to obtain contiguous horizontal planes at 1-mm intervals. In vitro, the probe was withdrawn along the left ventricular posterior wall of excised hearts. The borders of the RV were traced on each plane, allowing calculation of diastolic and systolic volumes, RV mass, RV ejection fraction, stroke volume, and cardiac output. RV wall thickness was measured. Echo volumes obtained in vitro were compared with cast volumes. Echo-derived cardiac output was compared with measurements of an ascending aortic Doppler flow probe. Echo-derived RV free wall mass was compared with true RV free wall weight. There was excellent agreement between cast and TEE volumes (y50.82x16.03, r50.88, P,0.01) and flow-probe and echo cardiac output (y51.00x10.45, r50.99, P,0.0001). Although echo-derived RV mass and wall thickness were well correlated with true RV weight, echo-derived RV mass underestimated true weight (y50.53x12.29, r50.81, P,0.0001). RV mass and wall thickness were greater in hypoxic mice than in normoxic mice (0.7860.19 versus 0.5160.14 mg/g, P,0.03, 0.5060.03 versus 0.3860.03 mm, P,0.04). Conclusions—TEE with an intravascular ultrasound catheter is a simple, accurate, and reproducible method to study RV size and function in mice. (Circulation. 1998;98:1015-1021.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of right ventricular structure and function in normoxic and hypoxic mice: a transesophageal echocardiographic study.

BACKGROUND Noninvasive cardiac evaluation is of great importance in transgenic mice. Transthoracic echocardiography can visualize the left ventricle well but has not been as successful for the right ventricle (RV). We developed a method of transesophageal echocardiography (TEE) to evaluate murine RV size and function. METHODS AND RESULTS Normoxic and chronically hypoxic mice (F(IO2)=0.11, 3 w...

متن کامل

Determination of the Effects of Digoxin on the Right Ventricular Function in Patients Undergoing Pneumonectomy

Introduction: Pneumonectomy is the standard treatment of lung cancer, even though patients should undergo several evaluations before surgery; deterioration of cardiopulmonary function after pulmonary resection is inevitable. We have evaluated the effects of digoxin on the improvement of right ventricular function and prevention of probable complications after lung resection surgery. Materials a...

متن کامل

ALUNG May 20/5

Klinger, James R., Rod R. Warburton, Linda A. Pietras, Oliver Smithies, Richard Swift, and Nicholas S. Hill. Genetic disruption of atrial natriuretic peptide causes pulmonary hypertension in normoxic and hypoxic mice. Am. J. Physiol. 276 (Lung Cell. Mol. Physiol. 20): L868–L874, 1999.—To determine whether atrial natriuretic peptide (ANP) plays a physiological role in modulating pulmonary hypert...

متن کامل

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Genetic disruption of atrial natriuretic peptide causes pulmonary hypertension in normoxic and hypoxic mice.

To determine whether atrial natriuretic peptide (ANP) plays a physiological role in modulating pulmonary hypertensive responses, we studied mice with gene-targeted disruption of the ANP gene under normoxic and chronically hypoxic conditions. Right ventricular peak pressure (RVPP), right ventricle weight- and left ventricle plus septum weight-to-body weight ratios [RV/BW and (LV+S)/BW, respectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998