Lipoprotein quantification: an electrophoretic method compared with the Lipid Research Clinics method.

نویسندگان

  • G R Warnick
  • T Nguyen
  • R O Bergelin
  • P W Wahl
  • J J Albers
چکیده

We compared a turbidimetric electrophoretic method (Lipidophor) for lipoprotein quantification with the standardized Lipid Research Clinics (LRC) method. In the Lipidophor procedure, major lipoproteins are separated by electrophoresis on agarose gels, precipitated on the gels with phosphotungstate-Mg2+ reagent, and the resulting turbidity is measured densitometrically. Measurements of relative turbidity were converted into lipoprotein cholesterol values by the use of numeric constants provided by the manufacturer. Among-day CVs (n = 46) for the Lipidophor method were 6.0%, 3.6%, and 9.9% for cholesterol in the alpha-, beta-, and pre-beta lipoproteins, respectively. The Lipidophor alpha-cholesterol was significantly lower (n = 171 specimens) than the LRC high-density lipoprotein (HDL) cholesterol (514 vs 586 mg/L), and beta-cholesterol was significantly higher than the corresponding LRC low-density lipoprotein (LDL) cholesterol values (1505 vs 1409 mg/L). The linear relation between the two methods for lipoprotein cholesterol quantification is as follows: Lipidophor alpha = 0.77 LRC HDL + 63 mg/L with correlation coefficient (r) of 0.87; Lipidophor beta = 0.95 LRC LDL + 166 mg/L (r = 0.96); Lipidophor pre-beta = 0.57 LRC very-low-density lipoprotein + 39 mg/L (r = 0.82). We derived a revised algorithm for estimating lipoprotein cholesterol from turbidity measurements. Lipoprotein cholesterol values by the Lipidophor method agree well with those obtained by the LRC method when these constants are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative measurement of lipoprotein surface charge by agarose gel electrophoresis.

The electrophoretic mobilities of low density lipoprotein (LDL) and six pure proteins in a 0.5% agarose gel have been compared to literature electrophoretic mobility values determined by the Tiselius moving boundary method. There is a strong correlation (r = 0.99) between the electrophoretic mobilities determined by the two techniques. The electrophoretic behavior of charged particles smaller t...

متن کامل

ElectrophoreticSeparationof High-DensityLipoproteinCholesterol Evaluated and Compared with the Modified LipidResearch Clinic Procedure

We evaluated a new agarose-gel-electrophoretic procedure (Corning) (I) for separatingandquantitating of highdensity lipoprotein cholesterol (HDLC), comparing it with the modified Lipid Research Clinics (LRC) procedure (heparin 183 kilounits/L, MnCI2 92 mmol/L) (U). Method I was insensitive to an HDLC concentration of 50 mg/L, but gave a linear dose-response curve between 130 and 1200 mg/L. Meth...

متن کامل

Quantification of cholesterol in all lipoprotein classes by the VAP-II method.

We have developed a high resolution microvolume Vertical Auto Profile (VAP) method for the simultaneous measurement of cholesterol in all lipoprotein classes, including lipoprotein[a] (Lp[a]) and intermediate density lipoprotein (IDL). This method, designated as VAP-II, uses a non-segmented continuous flow (controlled-dispersion flow) analyzer for the enzymatic analysis of cholesterol in lipopr...

متن کامل

Polyacrylamide-gel disc-electrophoresis as a screening procedure for serum lipoprotein abnormalities.

A polyacrylamide-gel disc-electrophoresis system is described that is suitable for screening sera with a wide range of lipid concentrations, and the results agree with analytical ultracentrifugation data. The Iipoprotein pattern so obtained was compared with that obtained by other recognized electrophoretic procedures. Lipoprotein determinations were done by polyacrylamide gel electrophoresis, ...

متن کامل

Simultaneous determination of serum cholesterol in high- and low-density lipoproteins with use of heparin, Ca2+, and an anion-exchange resin.

Cholesterol concentrations in serum high-density and low-density lipoproteins are simultaneously determined simply, specifically, and rapidly by use of the precipitation method with heparin, Ca2+, and an anion-exchange resin. The isolation of lipoproteins is reproducible, selective, and complete, as judged by electrophoresis on polyacrylamide gel and by immunoelectrophoresis, with use of sample...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 10  شماره 

صفحات  -

تاریخ انتشار 1982