A New Method for Extubation: Comparison between Conventional and New Methods

نویسندگان

  • Fardin Yousefshahi
  • Khosro Barkhordari
  • Ali Movafegh
  • Vida Tavakoli
  • Omalbanin Paknejad
  • Payvand Bina
  • Hadi Yousefshahi
  • Mahmood Sheikh Fathollahi
چکیده

BACKGROUND Extubation is associated with the risk of complications such as accumulated secretion above the endotracheal tube cuff, eventual atelectasia following a reduction in pulmonary volumes because of a lack of physiological positive end expiratory pressure, and intra-tracheal suction. In order to reduce these complications, and, based on basic physiological principles, a new practical extubation method is presented in this article. METHODS The study was designed as a six-month prospective cross-sectional clinical trial. Two hundred fifty-seven patients undergoing coronary artery bypass grafting (CABG) were divided into two groups based on their scheduled surgery time. The first group underwent the conventional extubation method, while the other group was extubated according to a new described method. Arterial blood gas (ABG) analysis results before and after extubation were compared between the two groups to find the effect of the extubation method on the ABG parameters and the oxygenation profile. RESULTS In all time intervals, the partial pressure of oxygen in arterial blood / fraction of inspired oxygen (PaO(2)/FiO(2)) ratio in the new method group patients was improved compared to that in the conventional method; some differences, like PaO(2)/FiO(2) four hours after extubation, were statistically significant, however (p value=0.0063). CONCLUSION The new extubation method improved some respiratory parameters and thus attenuated oxygenation complications and amplified oxygenation after extubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis and Comparison of Load Flow Methods for Distribution Networks Considering Distributed Generation

Conventional passive distribution networks are changing to modern active distribution networks which are not radial. Conventional load flow methods should be modified for new distribution networks analysis. In modern distribution networks distributed generation (DG) units are embedded with conventional and/or renewable resources. DG units are generally modeled as PV or PQ nodes which inject ...

متن کامل

Three-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method

In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...

متن کامل

A New Hybrid Heuristic Technique for Unit Commitment and Generation Scheduling

This paper proposes a novel technique for solving generation scheduling and ramp rate constrained unit commitment. A modified objective function associated with a new start-up cost term is introduced in this paper. The proposed method is used to solve generating scheduling problem satisfying SRR, minimum up and down time as well as ramp rate constraints. Two case studies are conducted to imp...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

مقایسه دو روش توموگرافی معمولی و رادیوویزیوگرافی در ارزیابی قبل از جراحی برای ایمپلنت‌های دندانی

Statement of Problem: Computed tomography (CT) has proved to be the most precise method to evaluate the quantity of jaw bones.In recent years, patient dose which is much more greater in CT than conventional methods has attracted more attention, and has brought the idea of using the conventional method in more accurate ways or applying new methods with lower doses.Purpose:radiovisiography for pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012