Developmental compensation of imposed astigmatism is not initiated by astigmatic accommodation in chickens
نویسندگان
چکیده
PURPOSE It is not clear whether emmetropization is confined to spherical refractive errors, or whether astiqmatic errors are also corrected via visual feedback. Experimental results from the animal model of the chicken are equivocal since compensation of imposed astimatic defocus was found in some but not all studies. Astigmatism could only be compensated by changes in the geometry of the cornea or lens. One has tested whether astigmatic spectacle lenses induce astigmatic accommodation as a possible first step of long-lasting compensation. METHODS Thirty-five chickens were treated with cylinder lenses (+3/0D or -3/0D) for 5 h. Refractions were determined at 1.38 m distance without cycloplegia in hand-held chicks before attaching the lenses, with the lenses on (0 h), and after 3 and 5 h, and after removal of the lenses. Spheres (S), cylinders (C) and axes (A) were determined using infrared photoretinocopy in three axes (the 'PowerRefractor', equipped with a 135 mm lens). RESULTS (1) The performance of the 'PowerRefractor' was tested in the chickens with trial lenses and gave correct refractions. (2) Astigmatic trial lenses induced refractive errors as expected from their powers in the case of +3/0D lenses: (S) +3.26 +/- 0.93D, (C) -3.45 +/- 0.87D). In the case of -3/0D lenses, slightly more hyperopic spheres were induced (refractions (S) +4.5 +/- 0.48D) but the cylinders were still as expected (-3.25 +/- 0.49D). The axes of astigmatism were correctly reproduced, since rotating the lenses changed the axes of the induced cylinders as expected. (3) Neither after 3 nor after 5 h of lens wear were there significant changes in the axes or the magnitude of astigmatism. Directly after removal of the lens, the refractions did not differ from their start-up values (with +3/0D lenses: (S) +3.31 +/- 1.05D vs. +3.22 +/- 0.76D, (C) -1.19 +/- 1.77D vs. -0.65 +/- 0.94D, (A) 96 +/- 49 vs. 113 +/- 45 deg; with -3/0D lenses: (S) 2.63 +/- 1.12D vs. 2.97 +/- 0.94D, (C) -1.11 +/- 1.15D vs. -0.53 +/- 0.56D, (A) 78 +/- 24 vs. 131 +/- 35 deg). CONCLUSIONS The most intuitive mechanism for compensation of astigmatic refractive errors, astigmatic accommodation, could not be demonstrated in chickens. In light of this finding, it seems unlikely that a visually controlled mechanism is operating during development to reduced astigmatism by changing corneal or lenticular growth.
منابع مشابه
Influence of different types of astigmatism on visual acuity
PURPOSE To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. METHODS The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were als...
متن کاملToric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power.
OBJECTIVES To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. METHOD In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically ind...
متن کاملAstigmatism of the Ex Vivo Human Lens: Surface and Gradient Refractive Index Age-Dependent Contributions.
PURPOSE We estimated the contribution of the gradient refractive index (GRIN) and lens surfaces to lens astigmatism and lens astigmatic angle as a function of age in human donor lenses. METHODS Human lenses were imaged, ex vivo, with 3D-spectral optical coherence tomography (OCT) and their back focal length was measured using laser ray tracing. The contribution of lens surfaces and GRIN to le...
متن کاملAstigmatism in infant monkeys reared with cylindrical lenses
To determine whether developing primate eyes are capable of growing in a manner that eliminates astigmatism, we reared infant monkeys with cylindrical spectacle lenses in front of one or both eyes that optically simulated with-the-rule, against-the-rule, or oblique astigmatism (+1.50-3.00x90, x180, x45 or x135). Refractive development was assessed by retinoscopy, keratometry and A-scan ultrason...
متن کاملSevere astigmatic blur does not interfere with spectacle lens compensation.
PURPOSE Whether either natural emmetropization or compensation for imposed spectacle lenses requires the visual system to distinguish myopic from hyperopic blur is controversial. Some have argued that the visual system need only respond to the magnitude of the blur. This study was undertaken to test whether adding large amounts of astigmatic image blur would cause myopia and interfere with comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 40 شماره
صفحات -
تاریخ انتشار 2000