Modelling of a proton spot scanning system using MCNP6

نویسندگان

  • Liyong Lin
  • Minglei Kang
  • Timothy D Solberg
  • Uwe Titt
  • Dragan Mirkovic
  • Gabriel O Sawakuchi
  • Christopher G Ainsley
  • Ajay Ghosh
  • O Ardenfors
چکیده

The aim of this work was to model the characteristics of a clinical proton spot scanning beam using Monte Carlo simulations with the code MCNP6. The proton beam was defined using parameters obtained from beam commissioning at the Skandion Clinic, Uppsala, Sweden. Simulations were evaluated against measurements for proton energies between 60 and 226 MeV with regard to range in water, lateral spot sizes in air and absorbed dose depth profiles in water. The model was also used to evaluate the experimental impact of lateral signal losses in an ionization chamber through simulations using different detector radii. Simulated and measured distal ranges agreed within 0.1 mm for R90 and R80, and within 0.2 mm for R50. The average absolute difference of all spot sizes was 0.1 mm. The average agreement of absorbed dose integrals and Bragg-peak heights was 0.9%. Lateral signal losses increased with incident proton energy with a maximum signal loss of 7% for 226 MeV protons. The good agreement between simulations and measurements supports the assumptions and parameters employed in the presented Monte Carlo model. The characteristics of the proton spot scanning beam were accurately reproduced and the model will prove useful in future studies on secondary neutrons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical Equipment and Systems

In January 2014, the Nagoya Proton Th erapy Center became the fi rst clinic in Japan to treat patients using proton spot scanning. Th e new system operates alongside two existing treatment rooms that started treating patients in February 2013 and use a passive scattering system. Th is means that the Nagoya Proton Th erapy Center now has three treatment rooms, two with rotating gantries and one ...

متن کامل

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

Evaluation of the relative biological effectiveness of spot-scanning proton irradiation in vitro

Variations in relative biological effectiveness (RBE) from a fixed value of 1.1 are critical in proton beam therapy. To date, studies estimating RBE at multiple positions relative to the spread-out Bragg peak (SOBP) have been predominantly performed using passive scattering methods, and limited data are available for spot-scanning beams. Thus, to investigate the RBE of spot-scanning beams, Chin...

متن کامل

A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size

PURPOSE A proton beam therapy (PBT) system has been designed which dedicates to spot-scanning and has a gating function employing the fluoroscopy-based real-time-imaging of internal fiducial markers near tumors. The dose distribution and treatment time of the newly designed real-time-image gated, spot-scanning proton beam therapy (RGPT) were compared with free-breathing spot-scanning proton bea...

متن کامل

SU-E-T-506: Dosimetric Study for Shallow-Seated Tumor Using Passive/active Scanning Proton Beam.

PURPOSE To investigate the possibility of using a single spot scanning proton beam to treat superficial lesions. METHODS A cylindrical phantom with a simulated superficial target (it seated 0.5-4cm depth from the surface, volume: 270cm3 ) was created in Eclipse treatment planning system. Three proton plans were generated: (a) a single AP uniform scanning beam with aperture and range compensat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017