Girder Support Scheme for the LCLS Undulator System

نویسنده

  • J. Welch
چکیده

Differential settlement of the foundation of the LCLS Undulator Hall will cause quadrupoles to move and the electron beam trajectory to distort. The resulting phase errors will decrease the FEL power and require time consuming beam-based alignment sessions to correct. By supporting quadrupoles on girders, with three quadrupoles to a girder, the foundationmotion induced phase error between the beam and the X Ray radiation can be reduced by a factor of 5 compared with supporting each quadrupole with a separate column. This comes about because the motions of three quadrupoles on a girder are linearly correlated so their effect on the beam is largely canceled out. Thus a girder support scheme can significantly help to extend the time between required beam based alignments and contribute to a more stable operation of the LCLS FEL beam.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lcls Undulator Commissioning, Alignment, and Performance *

The LCLS x-ray FEL has recently achieved its 1.5Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 μm) through the LCLS und...

متن کامل

Linac Coherent Light Source Undulator Rf Bpm System *

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of...

متن کامل

Binp Capacitive and Ultrasonic Hydrostatic Level Sensors

Slow ground motion study for future accelerator projects and alignment of large accelerator machine components with high accuracy are important tasks now. One of the prevalent tool for solution of these tasks are Hydrostatic Level Sensors designed to work into the Hydrostatic Levelling System, which is based on principle of communicating vessels. All water level measuring sensors are linked to ...

متن کامل

Coherent Radiation Effects in the Lcls Undulator∗

For X-ray Free-Electron Lasers such as LCLS and TESLA FEL, a change in the electron energy while amplifying the FEL radiation can shift the resonance condition out of the bandwidth of the FEL. The largest sources of energy loss is the emission of incoherent undulator radiation. Because the loss per electron depends only on the undulator parameters and the beam energy, which are fixed for a give...

متن کامل

Precision Measurement of the Undulator K Parameter Using Spontaneous Radiation

Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 Å, the relative precision of K must satisfy (ΔK/K)rms 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004