Short Technical Report Method for Printing Functional Protein Microarrays
نویسندگان
چکیده
Piezoelectric dispensing of proteins from borosilicate glass capillaries is a popular method of protein biochip fabrication that offers the advantages of sample recovery and noncontact with the printing substrate. However, little regard has been given to the quantitative aspects of dispensing minute volumes (1 nL or less) at the low protein concentrations (20 μg/mL or less) typically used in microprinting. Specifically, loss of protein sample due to nonspecific adsorption to the glass surface of the dispensing capillaries can limit the amount of protein delivered to the substrate. We demonstrate the benefits of a low ionic strength buffer containing the carrier protein BSA that effectively minimizes the ionic strength-dependent phenomenon of nonspecific protein adsorption to borosilicate glass. Over the concentration range of 20–2.5 μg/mL, the dispensing of a reference IgG in 10 mM PBS including 0.1% BSA resulted in the deposition of 3.6to 44-fold more IgG compared to the deposition of IgG in standard 150 mM PBS in the absence of BSA. Furthermore, when the IgG was dispensed with carrier protein, the resulting spots exhibited a more uniform morphology. In a direct immunoassay for cholera toxin, capture antibody spots dispensed in 10 mM PBS containing 0.1% BSA produced fluorescent signals that were 2.8to 4.3-fold more intense than antibody spots that were dispensed in 150 mM PBS without BSA. Interestingly, no differences were observed in the specific activities of the capture antibodies as a result of printing in the different buffers. The implications of these results on the future development of protein biochips are discussed.
منابع مشابه
Impact of medium properties on droplet release in a highly parallel nanoliter dispenser
We report about the correlation between satellite free droplet release and liquid viscosity in a highly parallel, pressure driven nanoliter dispenser. In extensive studies we found that for liquids of different viscosities the duration of the pressure pulse is the predominant effect compared to pressure amplitude. This result is of essential importance when actuation parameters have to be adopt...
متن کاملPhotoresist functionalisation method for high-density protein microarrays using photolithography
Since the last decade, there is a growing need for patterned biomolecules for various applications ranging from diagnostic devices to enabling fundamental biological studies with high throughput. Protein arrays facilitate the study of protein–protein, protein–drug or protein–DNA interactions as well as highly multiplexed immunosensors based on antibody–antigen recognition. Protein microarrays a...
متن کاملPatterned Protein Microarrays for Bacterial Detection
Patterned microarrays of antibodies were fabricated and tested for their ability to bind targeted bacteria. These arrays were used in a series of bacterial immunoassays to detect E. coli 0157:H7 and Renibacterium Salmoninarum (RS). Microarrays were fabricated using microcontact printing (μCP) and characterized using scanning probe microscopy (SPM). The high-resolution SPM imaging showed that ta...
متن کاملMicrointaglio Printing for Soft Lithography-Based in Situ Microarrays
Advances in lithographic approaches to fabricating bio-microarrays have been extensively explored over the last two decades. However, the need for pattern flexibility, a high density, a high resolution, affordability and on-demand fabrication is promoting the development of unconventional routes for microarray fabrication. This review highlights the development and uses of a new molecular litho...
متن کاملNormalization of qPCR array data: a novel method based on procrustes superimposition
MicroRNAs (miRNAs) are short, endogenous non-coding RNAs that function as guide molecules to regulate transcription of their target messenger RNAs. Several methods including low-density qPCR arrays are being increasingly used to profile the expression of these molecules in a variety of different biological conditions. Reliable analysis of expression profiles demands removal of technical variati...
متن کامل