Estimation of cardiac reserve by peak power: validation and initial application of a simplified index.
نویسندگان
چکیده
OBJECTIVES To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN Development of a simplified method of measurement and observational study. SETTING Tertiary referral centre for cardiothoracic disease. SUBJECTS For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.
منابع مشابه
Modeling and Improvement of Function of Solar Resources using Comparative Multipurpose Algorithm of PSO
In this article using comparative multi-purpose algorithm of PSO, optimum capacity of new resources and their spinning storage is defined. Spinning reserve requirements and optimized to maximize profit per unit is determined according to uncertainty. In fact by increasing the level of cost reservation, power supply increases but penalty of blackout decreases. In this paper in has been tried to ...
متن کاملOptimal Bidding Strategies of GENCOs in Day-Ahead Energy and Spinning Reserve Markets Based on Hybrid GA-Heuristic Optimization Algorithm
In an electricity market, every generation company (GENCO) attempts to maximize profit according to other participants bidding behaviors and power systems operating conditions. The goal of this study is to examine the optimal bidding strategy problem for GENCOs in energy and spinning reserve markets based on a hybrid GA-heuristic optimization algorithm. The heuristic optimization algorithm used...
متن کاملتحلیل حساسیت، واسنجی و اعتبارسازی مدل یوروسم برای پیشبینی رواناب در حوزه آبخیز کارون جنوبی
Models are helpful tools to predict runoff, sediment and soil erosion in watershed conservation practices. The objectives of this research were to investigate sensitivity analysis, calibration and validation of EUROSEM model in estimation of runoff in Tangh-e-Ravagh sub-basin of Karoun watershed. The model was tested in a one hectare experimental test site. The area was divided into nine elemen...
متن کاملApplication of Stochastic Programming to Determine Operating Reserves with Considering Wind and Load Uncertainties
Wind power generation is variable and uncertain. In the power systems with high penetration of wind power, determination of equivalent operating reserve is the main concern of systems operator. In this paper, a model is proposed to determine operating reserves in simultaneous market clearing of energy and reserve by stochastic programming based on scenarios generated via Monte Carlo simulation ...
متن کاملApplication of Demand Response Programs to Heavy Industries: a Case Study on a Regional Electric Company
In recent years, incremental rate of electrical demands made many challenges for policy makers of power systems. Besides, due to economic crisis and environmental concerns about the air pollution, the new investments in thermal power generation units have experienced a noticeable reduction. For this reason, the power system operators should propose novel approaches to make a balance between inc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 82 3 شماره
صفحات -
تاریخ انتشار 1999