An evaluation of the Technicon Autoanalyzer for automating complement-fixation tests.

نویسندگان

  • C E Taylor
  • J W Kershaw
  • G V Heimer
چکیده

Obviously there is need for a reliable means of automating complement-fixation tests. This paper offers an account of experience with an AutoAnalyzer adapted for this purpose. Results of syphilis screening tests done by the AutoAnalyzer compared with those of tests performed manually showed satisfactory agreement, the automated method being slightly less specific in our hands. There were no false negative results with the AutoAnalyzer if both Maltaner and Reiter protein antigens were used. The current design of the AutoAnalyzer contains three major shortcomings if it is to be used for large numbers of complement-fixation tests. First and foremost is the relatively slow sampling rate compatible with adequate sample discrimination. Second is the necessity for frequently replenishing the machine with samples. Third is the need for adjusting or cleaning the flow-cell during use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the Technicon AutoAnalyzer

SYNOPSIS Obviously there is need for a reliable means of automating complement-fixation tests. This paper offers an account of experience with an AutoAnalyzer adapted for this purpose. Results of syphilis screening tests done by the AutoAnalyzer compared with those of tests performed manually showed satisfactory agreement, the automated method being slightly less specific in our hands. There we...

متن کامل

Evaluation of automated large-scale screening tests for syphilis.

Two methods of performing serological screening tests for syphilis are compared. One consisted of the Venereal Diseases Reference Laboratory (VDRL) slide test, the cardiolipin Wassermann reaction (CWR), and the Reiter protein complement fixation test (RPCFT) performed manually; the other was a fully automated system using two Technicon AutoAnalyzers (AAII), one for the automated reagin test (AR...

متن کامل

Evaluation of an AutoAnalyzer method for quantitating anti-A and anti-B haemagglutinins in factor VIII preparations.

The continuous flow principle employed in the Technicon AutoAnalyzer has been adapted for the assay of anti-A and anti-B. The method has an acceptable degree of reproducibility and has been used, principally, for the quantitation of anti-A and anti-B in factor VIII concentrates of intermediate activity. It is, however, a method that can be applied to the assay of these antibodies in serum samples.

متن کامل

The Reiter protein complement-fixation test using the Auto-Analyzer.

A method for the Reiter protein complement-fixation test using the Techncon AutoAnalyzer is described. Two hundred and fifty sera were tested, when six false-positive and nine false-negative results were obtained when compared with results obtained by the manual method. Deep freezing the sera before testing on the AutoAnalyzer increased the sensitivity so that in a further 250 sera tested no fa...

متن کامل

Determination of serum or plasma glucose on the "AutoAnalyzer II" by use of the hexokinase reaction.

Manual procedures based on these reactions and involving the direct addition of serum to a single reagent are commonly used as emergency procedures in routine clinical chemistry laboratories of hospitals. We have adapted one of these methods, “Glucose 500-Pack” (Calbiochem, P.O. Box 12087, San Diego, Calif. 92772) to an automated method on the “AutoAnalyzer II” (Technicon Instruments Corp., Tar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 1968