Validated TLC-densitometry method for the simultaneous analysis of pyrethroid insecticides in agricultural and domestic products
نویسندگان
چکیده
UNLABELLED BACKGROUND Pyrethroids are widely used for the control of pests and insects, as pyrethroids are believed to pose little risk to human health and environment. However, exposure to the pyrethroids exceeding the label directions might adversely affect human health and environment. Hence a careful selection of environment friendly household product is required that must contain exactly the label claimed pyrethroids amount. RESULTS A sensitive and robust TLC-densitometric method for simultaneous quantification of commonly used synthetic pyrethroids including esbiothrin, alpha-cypermethrin and cis/trans permethrin in agricultural and domestic products has been developed and validated. TLC aluminum sheets, precoated with 0.2 mm thick layer of silica gel 60 F-254, were used for chromatographic process. Densitometric analysis of chromatoplates was carried out in absorbance mode at corresponding λmax of each pyrethroid. Equally valid common mobile phase for all pyrethroids consisted of hexane-dichloromethane-ethylacetate-formic acid (8:1.5:0.4:0.1 v/v/v/v) which provided sharp and symmetrical peaks of esbiothrin, alpha-cypermethrin, trans-permethrin and cis-permethrin, at Rf 0.31, 0.53, 0.6 and 0.65, respectively. Linear regression data for respective calibration curves showed a good linearity for all pyrethroids with r = 0.991-0.996. Limits of detection (LOD) and limits of quantification (LOQ) for all pyrethroids were found in the range of 1.6-2.8 and 4.9-8.5 ng/spot, respectively. CONCLUSIONS The developed method is applicable for separating the mixture of pyrethroids and at the same time, it is also valid for separating their isomers. The method is reproducible, precise and accurate for the quantitative determination of pyrethroids in agricultural and domestic products.
منابع مشابه
Effective separation and simultaneous analysis of anabolic androgenic steroids (AAS) in their pharmaceutical formulations by a validated TLC-densitometry method
BACKGROUND Anabolic androgenic steroids (AAS) are widely misused for the enhancement of performance in sports. Several drugs are available that contain different combinations or individual steroids in different dosage form. This paper describes a TLC densitometric method for simultaneous determination of four AAS of testosterone derivatives including testosterone propionate (TP), testosterone p...
متن کاملHPTLC-densitometry method development and validation for simultaneous determination of abacavir, lamivudine and zidovudine in combined dosage form
A simple, accurate and precise HPTLC- densitometry method for the simultaneousdetermination of abacavir, lamivudine and zidovudine in pharmaceutical tablet has beendeveloped. Separation of tablet components was performed on aluminum backed HPTLC plates(silica gel 60 F254 20×20 cm with 0.2 mm thickness, Camag, Muttenz, Switzerland ) usingmethanol : chloroform : acetonitrile (4 : 8 : 3 v/v). Good...
متن کاملValidation Thin Layer Chromatography for the Determination of Acetaminophen in Tablets and Comparison with a Pharmacopeial Method
Adsorption thin layer chromatography (NP-TLC) with densitometry has been established for the identification and the quantification of acetaminophen in three leading commercial products of pharmaceutical tablets coded as brand: P1 (Product no. 1), P2 (Product no. 2), and P3 (Product no. 3). Applied chromatographic conditions have separated acetaminophen from its related substances, namely, 4-ami...
متن کاملApplication of TLC- Densitometry Method for Simultaneous Estimation of Tramadol Hcl and Paracetamol in Pharmaceutical Dosage Forms
A rapid, selective and precise high performance thin layer chromatographic method was developed and validated for simultaneous estimation of Tramadol Hcl and Paracetamol in pharmaceutical dosage forms. The method employed TLC aluminium plates precoated with silica gel 60F254 as the stationary phase. The solvent system consisted of Chloroform: Ethanol (7:3 v/v). This system was found to give com...
متن کاملDetermination of active ingredient in synthetic pyrethroid formulations by high-performance thin-layer chromatography/densitometry.
A new, simple, precise, and rapid high-performance thin-layer chromatography (HPTLC) method was developed for the analysis of commercial emulsifiable concentrate (EC) formulations of cypermethrin, alpha-cypermethrin, and lambda-cyhalothrin. A known amount of reference grade synthetic pyrethroid and its EC formulation was subjected to TLC, and the amount of pesticide present in the active ingred...
متن کامل