Recommendations on detectors and quality control procedures for brachytherapy beta sources.

نویسندگان

  • Robert P Kollaard
  • Wim J F Dries
  • Herman J van Kleffens
  • Tony H L Aalbers
  • Hans van der Marel
  • Hans P A Marijnissen
  • Marleen Piessens
  • Dennis R Schaart
  • Henk de Vroome
چکیده

BACKGROUND AND PURPOSE It is estimated that one third of the institutes applying clinical beta sources does not perform independent dosimetry. The Netherlands commission on radiation dosimetry (NCS) recently published recommended quality control procedures and detectors for the dosimetry of beta sources. The main issues of NCS Report 14 are summarized here. MATERIALS AND METHODS A dosimetry survey was performed among 23 institutes in The Netherlands and Belgium. Well ionization chambers, a plastic scintillator, plane-parallel ionization chamber, diode and radiochromic film were used for determination of source strength (dose rate at reference distance) and uniformity of intravascular and ophthalmic sources. The source strength of multiple sources of each type was measured and compared with the source strength specified by the manufacturer. RESULTS The standard deviation of the difference between measured and specified source strength was mostly about 3%, but varied between 0.8 and 15.8% depending on factors such as source type, detector, phantom and manufacturers calibration. The average non-uniformity was about 7% for intravascular sources and 20% for ophthalmic sources. It is estimated that the total relative standard uncertainty can be kept below +/-4% (1 sigma) with all detectors tested. Maximum deviations in source strength of 10% and a non-uniformity below 10% (intravascular) and 30% (ophthalmic) are recommended. CONCLUSIONS Dosimetric and non-dosimetric quality control procedures on beta sources are recommended. They enable standardized measurements, including the determination of relative source strength and non-uniformity. Absolute calibrations depend on the future introduction of primary standards for clinical beta sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Third-party brachytherapy source calibrations and physicist responsibilities: report of the AAPM Low Energy Brachytherapy Source Calibration Working Group.

The AAPM Low Energy Brachytherapy Source Calibration Working Group was formed to investigate and recommend quality control and quality assurance procedures for brachytherapy sources prior to clinical use. Compiling and clarifying recommendations established by previous AAPM Task Groups 40, 56, and 64 were among the working group's charges, which also included the role of third-party handlers to...

متن کامل

TG-60 dosimetry parameters calculation for the β-emitter 153Sm brachytherapy source using MCNP

Background: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for β sources. Radioactive biocompatible and biodegradable 153Sm glass seed without encapsulation is a β- emitter with a short half life and delivers a high dose rate to the tumor in the millimeter range. In this work the dosimetry parameters of the ...

متن کامل

Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for Y microsphere brachytherapy in the treatment of hepatic malignancies

Yttrium-90 microsphere brachytherapy of the liver exploits the distinctive features of the liver anatomy to treat liver malignancies with beta radiation and is gaining more wide spread clinical use. This report provides a general overview of microsphere liver brachytherapy and assists the treatment team in creating local treatment practices to provide safe and efficient patient treatment. Sugge...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 2006