Potentiometric NO2 Sensors Based on Thin Stabilized Zirconia Electrolytes and Asymmetric (La0.8Sr0.2)0.95MnO3 Electrodes
نویسندگان
چکیده
Here we report on a new architecture for potentiometric NO2 sensors that features thin 8YSZ electrolytes sandwiched between two porous (La0.8Sr0.2)0.95MnO3 (LSM95) layers-one thick and the other thin-fabricated by the tape casting and co-firing techniques. Measurements of their sensing characteristics show that reducing the porosity of the supporting LSM95 reference electrodes can increase the response voltages. In the meanwhile, thin LSM95 layers perform better than Pt as the sensing electrode since the former can provide higher response voltages and better linear relationship between the sensitivities and the NO2 concentrations over 40-1000 ppm. The best linear coefficient can be as high as 0.99 with a sensitivity value of 52 mV/decade as obtained at 500 °C. Analysis of the sensing mechanism suggests that the gas phase reactions within the porous LSM95 layers are critically important in determining the response voltages.
منابع مشابه
A New Low-Temperature Electrochemical Hydrocarbon and NOx Sensor
In this article, a new investigation on a low-temperature electrochemical hydrocarbon and NOx sensor is presented. Based on the mixed-potential-based sensing scheme, the sensor is constructed using platinum and metal oxide electrodes, along with an Yttria-Stabilized Zirconia (YSZ)/Strontium Titanate (SrTiO₃) thin-film electrolyte. Unlike traditional mixed-potential sensors which operate at high...
متن کاملCorrelation of sensing behavior of mixed potential sensors with chemical and electrochemical properties of electrodes
The mixed potential response for NO and NO2 from two different oxide electrodes on yttria-stabilized zirconia (YSZ) was examined at 500 jC. The two electrodes were La0.6Sr0.4Fe0.8Co0.2O3 (LSFCO) and Cr2O3. Sensors made with LSFCO electrodes had consistently lower sensitivity towards NOx as compared to those with Cr2O3 and the focus of this paper is to understand the fundamental reasons for the ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملInvestigation of the mechanical properties of various yttria stabilized zirconia based thin films prepared by aqueous tape casting
In this study various yttria doped zirconia based thin films were prepared by the aqueous tape casting method. The rheological property of the paste was studies. The phase content and microstructure of the samples was investigated by X-ray diffraction and scanning electron microscope, respectively. The mechanical properties of thin films were studied by Vickers microhardness and nanoindentatio...
متن کامل