Coherent X-ray imaging: bridging the gap between atomic and micro-scale investigations.

نویسندگان

  • Marco Stampanoni
  • Andreas Menzel
  • Ben Watts
  • Kevin S Mader
  • Oliver Bunk
چکیده

We present a review of state-of-the art X-ray imaging techniques based on partially coherent synchrotron radiation. Full-field X-ray tomography, X-ray ptychography, scanning small-angle X-ray scattering, and scanning transmission X-ray microscopy are imaging techniques that gather structural information at spatial resolution ranging from several microns to a few tens of nanometers in both real- and reciprocal space. These methods exploit contrast mechanisms based on absorption, phase, and spectroscopic signals. We provide examples of how these techniques can be applied to address scientific questions ranging from imaging of biological samples, to foam rheology, and cement composition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry of Occupational Radiation around Panoramic X-ray Apparatus

Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...

متن کامل

Band-Gap Tuning Of Electron Beam Evaporated Cds Thin Films

The effect of evaporation rate on structural, morphological and optical properties of electron beam evaporated CdS thin films have been investigated. CdS thin film deposited by electron beam evaporation method in 12nm/min and 60nm/min evaporation rates on glass substrates. X-ray diffraction, scanning electron microscopy, UV-Vis-NIR spectroscopy and Atomic Force Microscopy were used to character...

متن کامل

Reversal Trend of Hounsfield Unit Values of Substances with High and Low Effective Atomic Numbers

Introduction: In dual-energy computed tomography (DECT), the Hounsfield values of a substance measured at two different energies are the basic data for finding the chemical properties of a substance. The trends of Hounsfield unit (HU) alterations following the changes in energy are different between the materials with high and low Zeff. The present study aim...

متن کامل

Incoherent x-ray scattering in single molecule imaging

Imaging of the structure of single proteins or other biomolecules with atomic resolution would be enormously beneficial to structural biology. X-ray freeelectron lasers generate highly intense and ultrashort x-ray pulses, providing a route towards imaging of single molecules with atomic resolution. The information on molecular structure is encoded in the coherent x-ray scattering signal. In con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chimia

دوره 68 1-2  شماره 

صفحات  -

تاریخ انتشار 2014