Cut-off value of FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction in a Korean population

نویسندگان

  • Kyung Soo Chung
  • Ji Ye Jung
  • Moo Suk Park
  • Young Sam Kim
  • Se Kyu Kim
  • Joon Chang
  • Joo Han Song
چکیده

BACKGROUND Forced expiratory volume in 1 second (FEV1)/forced expiratory volume in 6 seconds (FEV6) has been proposed as an alternative to FEV1/forced vital capacity (FVC) for detecting airway obstruction. A fixed cut-off value for FEV1/FEV6 in a Korean population is lacking. We investigated a fixed cut-off for FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction. MATERIALS AND METHODS We used data obtained in the 5 years of the Fifth and Sixth Korean National Health and Nutrition Examination Survey. A total of 14,978 participants aged ≥40 years who underwent spirometry adequately were the study cohort. "Airway obstruction" was a fixed cut-off FEV1/FVC <70% according to the Global Initiative for Chronic Obstructive Lung Disease guidelines. We also used European Respiratory Society/Global Lung Initiative 2012 equations for the FEV1/FVC lower limit of normal. RESULTS Among the 14,978 participants (43.5% male, 56.5% female; mean age: 56.9 years for men and 57.0 years for women), 14.0% had obstructive lung function according to a fixed cut-off FEV1/FVC <70%. Optimal FEV1/FEV6 cut-off for predicting FEV1/FVC <70% was 75% using receiver operating characteristic curve analyses (area under receiver operating characteristic curve =0.989, 95% confidence interval 0.987-0.990). This fixed cut-off of FEV1/FEV6 showed 93.8% sensitivity, 94.8% specificity, 74.7% positive predictive value, 98.9% negative predictive value, and 0.8 Cohen's kappa coefficient. When compared with FEV1/FVC < lower limit of normal, FEV1/FEV6 <75% tended to over-diagnose airflow limitation (just like a fixed cut-off of FEV1/FVC <70%). When grouped according to age and FEV1 (%), FEV1/FEV6 <75% diagnosed more airway obstruction in older participants and mild-moderate stages compared with FEV1/FVC <70%. CONCLUSION A valid fixed cut-off for detecting airway obstruction in a Korean population is FEV1/FEV6 of 75%, but should be used with caution in older individuals and those with mild-moderate airway obstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixed Cut-Off for FEV1/FEV6 and FEV6 in Detection of Obstructive and Restrictive Patterns

BACKGROUND Chronic obstructive pulmonary diseases (COPD) have been defined by the Global Initiative for Chronic Obstructive Lung Disease (GOLD) as irreversible conditions which are diagnosed by fixed cut-off points of FEV1/FVC. OBJECTIVE The aim of this study was to determine the cut-off points for FEV1/FEV6 ratio and FEV6 as alternatives for FEV1/FVC and FVC in detection of airway obstructio...

متن کامل

Efficacy of the FEV1/FEV6 ratio compared to the FEV1/FVC ratio for the diagnosis of airway obstruction in subjects aged 40 years or over.

The present cross-sectional, population-based study was designed to evaluate the performance of the FEV1/FEV6 ratio for the detection of airway-obstructed subjects compared to the FEV1/FVC <0.70 fixed ratio test, as well as the lower limit of normality (LLN) for 1000 subjects (3)40 years of age in the metropolitan area of São Paulo, SP, Brazil. After the exclusion of 37 (3.7%) spirometries, a t...

متن کامل

Determination of the efficacy of FEV6 as a surrogate for FVC in the diagnostic screening for chronic obstructive pulmonary disease through the comparison of FEV1/FVC and FEV1/FEV6 ratios.

OBJECTIVE To determine the efficacy of using forced expiratory volume in six seconds (FEV6) as a surrogate for forced vital capacity (FVC) in the diagnostic screening for chronic obstructive pulmonary disease (COPD) by comparing FEV1/FVC ratios with FEV1/FEV6 ratios. METHODS In November of 2003, on World COPD Day, we conducted a campaign of diagnostic screening for COPD. The participants comp...

متن کامل

[Airflow limitation in Brazilian Caucasians: FEV1/FEV6 vs. FEV1/FVC].

OBJECTIVE To evaluate the use of the forced expiratory volume in one second/forced expiratory volume in six seconds (FEV1/FEV6) ratio as an alternative to the FEV1/forced vital capacity (FVC) ratio in the detection of mild airway obstruction. METHODS Reference equations for the Brazilian population in 2006 were used in order to determine the lower limits of normality for the FEV1/FEV6 and FEV...

متن کامل

Reliability of FEV1/FEV6 to Diagnose Airflow Obstruction Compared with FEV1/FVC: The PLATINO Longitudinal Study

QUESTION A 6-second spirometry test is easier than full exhalations. We compared the reliability of the ratio of the Forced expiratory volume in 1 second/Forced expiratory volume in 6 seconds (FEV1/FEV6) to the ratio of the FEV1/Forced vital capacity (FEV1/FVC) for the detection of airway obstruction. METHODS The PLATINO population-based survey in individuals aged 40 years and over designed t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016