Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation.
نویسندگان
چکیده
AIM To prospectively investigate changes in the area of the anterior capsule opening, and intraocular lens (IOL) decentration and tilt after implantation of a hydrogel IOL. METHODS 100 patients underwent implantation of a hydrogel IOL in one eye and an acrylic IOL implantation in the opposite eye. The area of the anterior capsule opening, and the degree of IOL decentration and tilt were measured using the Scheimpflug videophotography system at 3 days, and at 1, 3, and 6 months postoperatively. RESULTS The mean anterior capsule opening area decreased significantly in both groups. At 6 months postoperatively, the area in the hydrogel group was significantly smaller than that in the acrylic group. The mean percentage of the area reduction in the hydrogel group was also significantly greater than that in the acrylic group, being 16.9% in the hydrogel group and 8.8% in the acrylic group. In contrast, IOL decentration and tilt did not progress in either group. No significant differences were found in the degree of IOL decentration and tilt throughout the follow up period. CONCLUSIONS Contraction of the anterior capsule opening was more extensive with the hydrogel IOL than with the acrylic IOL, but the degree of IOL decentration and tilt were similar for the two types of lenses studied.
منابع مشابه
Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
PURPOSE To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic ...
متن کاملAnterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome.
AIMS To examine the extent of anterior capsule contraction as well as intraocular lens (IOL) decentration and tilt following implant surgery in eyes with pseudoexfoliation syndrome (PE). METHODS 53 eyes from 53 patients with PE and 53 control eyes from 53 age matched patients, undergoing phacoemulsification and implant surgery, were recruited. The anterior capsule opening area and the amounts...
متن کاملOutcomes of modified capsular tension ring versus sulcus-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome
Purpose: To determine the outcomes of implantation of a modified Capsular Tension Ring (CTR) and a Posterior Chamber Intraocular Lens (PCIOL) in patients with subluxated lens secondary to Marfan Syndrome (MFS). Materials and methods: A total of 21 eyes of 12 patients with subluxated lens secondary to MFS undergoing Posterior Chamber Intraocular Lens (PCIOL) from March 2004 to February 2005 were...
متن کاملA prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.
AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...
متن کاملTreatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 85 11 شماره
صفحات -
تاریخ انتشار 2001