An Application of Prony’s Sum of Exponentials Method to Pharmacokinetic Data Analysis
نویسندگان
چکیده
We discuss the basic concept of compartmental modelling in pharmacokinetics and demonstrate that all the solutions admitted by multi-compartment models of classical pharmacokinetics are expressed as linear combinations of exponential functions of time. This lends itself to data analysis that depends on fitting exponential functions to finite size sets. A mathematical method developed a long time ago to deal with this type of problem is called Prony’s method. We discuss the usefulness of this method in pharmacokinetic modeling and apply it to a particular data set obtained for the drug mibefradil. In spite of the method’s power in dealing with well-behaved data sets, we indicate the existence of severe limitations since real concentration curves coming from pharmacokinetic data are seldom purely exponential. PACS: 82.39.-k, 05.45.Df, 61.43.Hv, 82.30.-b
منابع مشابه
Study on Feature Extraction of Semiconductor Gas Sensor Based on Prony’s Method
In this study, feature extraction from a transient response of a semiconductor gas sensor is investigated. For the sensor response given as the step response of the fi rstorder lag system, the sensor output can be approximated as a sum of exponentials by Prony’s method. The model parameters can be estimated as the time constant and the gain, which are inherent parameters for each gas. The param...
متن کاملImproving envelopment in data envelopment analysis by means of unobserved DMUs: an application of banking industry
In data envelopment analysis, the relative efficiency of a decision making unit (DMU) is defined as the ratio of the sum of its weighted outputs to the sum of its weighted inputs allowing the DMUs to freely allocate weights to their inputs/outputs. However, this measure may not reflect a the true efficiency of a DMU because some of its inputs/outputs may not contribute reasonably in computing t...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملOn the consistency of Prony’s method
Modification’s of Prony’s classical technique for estimating rate constants in exponential fitting problems have many contemporary applications. Here the consistency of Prony’s method and of related algorithms based on maximum likelihood is discussed as the number of observations n → ∞ by considering the simplest possible models for fitting sums of exponentials to observed data. Two sampling re...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006