A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes

نویسندگان

  • Tiago B Ferreira
  • Filomena J Ribeiro
چکیده

PURPOSE To assess the accuracy of corneal astigmatism evaluation measured by four techniques, Orbscan IIz(®), Lenstar LS900(®), Cassini(®), and Total Cassini (anterior + posterior surface), in pseudophakic eyes. PATIENTS AND METHODS A total of 30 patients (46 eyes) who had undergone cataract surgery with the implantation of a monofocal intraocular lens (AcrySof IQ) were assessed after surgery. For each eye, subjective assessment of astigmatism and its axis was performed. Minimum, maximum, and mean keratometry and astigmatism and its axis were evaluated using the four measurement techniques. All measurements were compared with the subjective measurements. Agreement between each measurement technique and subjective assessment was evaluated using Bland-Altman plots. Linear regressions were performed and compared. RESULTS Linear regression analysis of astigmatism axis showed very high R (2) for all models, with Total Cassini showing the least difference to the unit slope (0.052) and the least difference to a null constant (3.790), although not statistically different from the other models. Regarding astigmatism value, the Cassini and Total Cassini models were similar and statistically better than the Lenstar model. Cassini and Total Cassini showed better J0 compared with Orbscan. CONCLUSION On linear regression models, Cassini and Total Cassini showed the best performance regarding astigmatism value. Cassini and Total Cassini also showed the least J0 deviation from the Cartesian origin compared with Orbscan, which had the lowest performance. Total corneal measurement with the color LED topographer seems to be a better technique for astigmatism assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography

PURPOSE To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. METHODS Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot reflection topographer (Cassini; i-Optics). Two patient groups were studied, a younger-age group A...

متن کامل

Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery

BACKGROUND To examine the influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery. METHODS The study enrolled 64 pseudophakic eyes of 50 patients (71.8 ± 9.9 years old, mean ± standard deviation) who had undergone phacoemulsification with non-toric IOL implantation. Refractive astigmatism was measured using an auto ref-ker...

متن کامل

Pseudophakic residual astigmatism.

We investigated pseudophakic residual astigmatism in order to minimize postoperative refractive astigmatism. We examined 110 eyes of 87 patients who had undergone phacoemulsification with small incision and posterior chamber intraocular lens (IOL) implantation. Corneal astigmatism was measured using an autokeratometer (RK-5, canon), refractive astigmatism by manifest refraction, and residual as...

متن کامل

Apparent accommodation in pseudophakic eyes with refractive against-the-rule, with-the-rule and minimum astigmatism.

AIM To compare the magnitude of apparent accommodation in pseudophakic eyes with refractive against-the-rule (ATR), with-the-rule (WTR) and minimum astigmatism. Factors associated with apparent accommodation were also examined in each group. METHODS In total, 87 pseudophakic eyes (87 patients) that underwent monofocal intraocular lens (IOL) implantation after uneventful cataract surgery were ...

متن کامل

Apparent accommodation in pseudophakic eyes as measured with visually evoked potentials.

We measured apparent accommodation with pattern reversal visually evoked cortical potentials in 27 pseudophakic eyes after the implantation of posterior chamber intraocular lenses. The patients ranged in age from 47-83 years. The amplitude of accommodation was not significantly different between pseudophakic eyes and normal phakic eyes. Apparent accommodation was inversely proportional to the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016