An improved chamber for the short-circuiting of epithelia.

نویسندگان

  • J A Dow
  • W R Harvey
  • M G Wolfersberger
  • B Boyes
چکیده

Since the pioneering work of Ussing & Zerahn (1951), the design of short-circuit apparatus has been modified only slightly. Such chambers generally consist of two halves, between which the epithelium is stretched. The assembly is clamped together and filled with saline, which is circulated in each half chamber by gas lift pumps, usually connected to the main chamber with plastic pipes. There are two current electrodes, one at each end of the chamber, and usually two voltagesensing electrodes close to the tissue. The current passed through the chamber is adjusted until the p.d. between the sensing electrodes becomes zero. Under such conditions, only actively transported ions move across the tissue, and the shortcircuit current is a precise measure of the net flux of charged species. Shortcircuiting is thus a method of choice for investigating transport phenomena in epithelia. In this paper, we describe a chamber which differs significantly from the classical design, and illustrate its performance with specific reference to a tissue containing a potent electrogenic pump, the midgut of the lepidopteran larva, Manduca sexta (Harvey, Cioffi, Dow & Wolfersberger, 1983). The chamber (Fig. 1) consists of a short cylinder of Perspex, drilled axially with an 8-mm hole. Current electrodes of thin silver sheet are held against either end by Perspex endplates (Fig. 1), which are held to the main chamber with screws. The central bore is divided into two chamber 'halves' by a milled slot, into which the tissue-bearing aperture (Fig. 1) is inserted. Three voltage-sensing electrodes (Ag/AgCl wires, insulated to 1 mm below the tip, for normal use, or agar bridges to calomel electrodes for Ag-sensitive tissues) are inserted into the chamber, through rubber seals, on either side of the aperture (A-C in Fig. 1). The three electrode arrangement compensates for the resistivity of the saline, when this low resistivity tissue (10011cm) is short-circuited (Wood & Moreton, 1978). Circulation of fluid is accomplished with gas-lift pumps, which are integral within the main chamber block. Gas (oxygen or nitrogen) is supplied at constant pressure to the two gas inlets (F,G, Fig. 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large Eddy Simulation of Flow and Tracer Transport in Multichamber Ozone Contactors

Three-dimensional numerical analyses of flow and transport characteristics in two representative multichamber ozone contactor models with different chamber width were conducted using large eddy simulation LES . Both time-averaged and instantaneous flow patterns suggest that the flow is characterized by the occurrence of large turbulent structures leading to extensive short-circuiting between ch...

متن کامل

An Efficiency Studying of an Ion Chamber Simulation Using Vriance Reduction Techniques with EGSnrc

Background: Radiotherapy is an important technique of cancer treatment using ionizing radiation. The determination of total dose in reference conditions is an important contribution to uncertainty that could achieve 2%. The source of this uncertainty comes from cavity theory that relates the in-air cavity dose and the dose to water. These correction factors are determined from Monte Carlo calcu...

متن کامل

Synthesizing Short-Circuiting Validation of Data Structure Invariants

This paper presents incremental verification-validation, a novel approach for checking rich data structure invariants expressed as separation logic assertions. Incremental verification-validation combines static verification of separation properties with efficient, shortcircuiting dynamic validation of arbitrarily rich data constraints. A data structure invariant checker is an inductive predica...

متن کامل

The Physical Role of Transverse Deep Zones in Improving Constructed Treatment Wetland Performance

Velocity heterogeneity is often present in wetland systems and results in some influent water remaining in the wetland for less than the expected residence time. This phenomenon, known as short-circuiting, alters the distribution of the chemical and biological transformations that occur within the wetland and decreases performance in constructed treatment wetlands. In this thesis, field observa...

متن کامل

Effect of ethanol extracts of three Chinese medicinal plants with anti-diarrheal properties on ion transport of the rat intestinal epithelia.

Effects of ethanol extracts of three Chinese medicinal plants, namely, Qinpi (Fraxini cortex), Kushen (Sophora flavescens, AITON), and Huanglian (Coptis teeta, WALLICH), on ion transport of the rat intestinal epithelia were determined in this study. Rat intestinal epithelia mounted in an Ussing chamber attached to a voltage/current clamp were used for measuring changes in the short circuit curr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of experimental biology

دوره 114  شماره 

صفحات  -

تاریخ انتشار 1985