Lower limb intracast pressures generated by different types of immobilisation casts

نویسندگان

  • Salma Chaudhury
  • Alexandra Hazlerigg
  • Anuhya Vusirikala
  • Joseph Nguyen
  • Stuart Matthews
چکیده

AIM To determine if complete, split casts and backslabs [plaster of Paris (POP) and fiberglass] generate different intracast pressures and pain. METHODS Increased swelling within casts was modeled by a closed water system attached to an expandable bag placed directly under different types of casts applied to a healthy lower limb. Complete fiberglass and POP casts, split casts and backslabs were applied. Twenty-five milliliter aliquots of saline were injected into the system and the generated intracast pressures were measured using a sphygmomanometer. The subject was blinded to the pressure scores to avoid bias. All casts were applied to the same right limb on the same subject to avoid the effects of variations in anatomy or physiology on intracast pressures. Pain levels were evaluated using the Visual Analogue Score after each sequential saline injection. Each type of cast was reapplied four times and the measurements were repeated on four separate occasions. Sample sizes were determined by a pre-study 90% power calculation to detect a 20% difference in intracast pressures between cast groups. RESULTS A significant difference between the various types of casts was noted when the saline volume was greater than 100 mL (P = 0.009). The greatest intracast pressure was generated by complete fiberglass casts, which were significantly higher than complete POP casts or backslabs (P = 0.018 and P = 0.008 respectively) at intracast saline volumes of 100 mL and higher. Backslabs produced a significantly lower intracast pressure compared to complete POP only once the saline volume within casts exceeded 225 mL (P = 0.009). Intracast pressures were significantly lower in split casts (P = 0.003). Split POP and fiberglass casts produced the lowest intracast pressures, even compared to backslabs (P = 0.009). Complete fiberglass casts generated the highest pain levels at manometer pressures of 75 mmHg and greater (P = 0.001). Split fiberglass casts had significantly reduced pain levels (P = 0.001). In contrast, a split complete POP cast did not produce significantly reduced pain levels at pressures between 25-150 mmHg. There was no difference in pain generated by complete POP and backslabs at manometer pressures of 200 mmHg and lower. CONCLUSION Fibreglass casts generate significantly higher intracast pressures and pain than POP casts. Split casts cause lower intracast pressures regardless of material, than complete casts and backslabs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Venous Thromboembolism Prophylaxis in Patients Immobilised in Plaster Casts

Introduction: Lower limb immobilisation in plaster is associated with a risk of venous thromboembolism. It has been demonstrated that prophylaxis with low molecular weight heparin can reduce this risk. Recent guidelines have therefore recommended thromboprophylaxis for all patients immobilised in plaster and with one further risk factor. Method: In order to standardise the thromboprophylaxis pr...

متن کامل

A comparison between the dimensions of positive transtibial residual limb molds prepared by air pressure casting and weight-bearing casting methods

Background: Creating a socket with proper fit is an important factor to ensure the comfort and control of prosthetic devices. Several techniques are commonly used to cast transtibial stumps but their effect on stump shape deformation is not well understood. This study compares the dimensions, circumferences and volumes of the positive casts and also the socket comfort between two casting method...

متن کامل

Is Driving Safe with Upper Limb Plaster Casts? Üst Ekstremite Alçıları ile Sürüş Güvenli midir?

Objective: The purpose of this study is to investigate the ability and safety of driving with commonly used upper limb casts, and to determine the effect of hand dominance. Material and Methods: Two healthy drivers, one of them right-handed and the other left-handed (confirmed with the Edinburgh handedness inventory), were selected. The vehicles used in this study were the 2006 model Volkswagen...

متن کامل

The effect of different types of foot orthoses on the biomechanical variables, lower extremity muscular activity and balance in elderly: A systematic review study

Older adults demonstrate increased amounts of postural sway, which may ultimately lead to falls. The purpose of this systematic review was to investigate the effect of different foot orthoses on lower limb biomechanical variables, lower limb muscular activity, and balance in elderly people. Examining texts based on the search on the Magiran, Google Schoolar, Pubmed, Scopus, and SIVILICA sites w...

متن کامل

Calamine lotion to reduce skin irritation in children with cast immobilisation.

PURPOSE. To evaluate the effect of calamine lotion in reducing skin irritation in children with cast immobilisation and to identify factors correlating with skin irritation. METHODS. 250 children aged 6 to 15 years who underwent cast immobilisation for limb fractures were assigned into calamine (n=122) and non-calamine (n=128) groups. Data were collected at the time the cast was applied and rem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017