Accuracy of two impression techniques with angulated implants.

نویسندگان

  • Heather J Conrad
  • Igor J Pesun
  • Ralph DeLong
  • James S Hodges
چکیده

STATEMENT OF PROBLEM Accurate recording of implant locations is required so that definitive restorations are properly supported and do not place additional stress on the implants. Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. PURPOSE The purpose of this study was to determine the effect the combined interaction of impression technique, implant angulation, and implant number has on the accuracy of implant definitive casts. MATERIAL AND METHODS One definitive stone cast was fabricated for each of 6 experimental groups and 1 control group. All 7 definitive casts had 3 implants arranged in a triangular pattern creating a plane. In the 6 experimental groups, the center implant was perpendicular to the plane of the cast while the outer implants had 5, 10, or 15 degrees convergence towards or divergence away from the center implant. The control definitive cast had all 3 implants parallel to each another and perpendicular to the plane of the cast. Five open tray and 5 closed tray addition silicone impressions were made of each definitive cast. Impressions were poured with type IV dental stone, and a fine tip measuring stylus was used to record multiple axis (X-Y-Z) coordinates on the top surface of the implant hex and on the cast base. Computer software was used to align the data sets and vector calculations determined the difference in degrees between the implant angles in the definitive cast and the duplicate casts. Statistical analysis used repeated-measures ANOVA (alpha=.05) with post-hoc tests of significant interactions. RESULTS The angle errors for the closed and open tray impression techniques did not differ significantly (P=.22). Implant angulations and implant numbers differed in average angle errors but not in any easily interpreted pattern (P<.001). The combined interaction of impression technique, implant angulation, and implant number had no effect on the accuracy of the duplicate casts compared to the definitive casts (P=.19). CONCLUSIONS The average angle errors for the closed and open tray impression techniques did not differ significantly. There was no interpretable pattern of average angle errors in terms of implant angulation and implant number. The magnitude of distortion was similar for all combinations of impression technique, implant angulation, and implant number.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

Statement of the Problem Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the ...

متن کامل

Accuracy of impressions with different impression materials in angulated implants.

PURPOSE To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. MATERIALS AND METHODS Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were ...

متن کامل

Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)

BACKGROUND Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. METHODS Three Osseolink implants were placed in three reference mo...

متن کامل

تعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالب‌گیری

Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...

متن کامل

بررسی مقایسه‌ای تری‌های ‌قالب‌گیری تمام قوس و نیم قوس بر دقت ابعادی و زاویه‌ای قالب‌های تهیه‌ شده از ایمپلنت‌های زاویه‌دار

Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays. Materials and Methods: Four implants (4.3 &times; 12 mm) (Implantium, Dentium) were plac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 97 6  شماره 

صفحات  -

تاریخ انتشار 2007