Early Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup
نویسندگان
چکیده
Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zimmer Biomet, Warsaw, IN) for total hip arthroplasty. Between 2007 and 2013, the registry with 476 hip joints was reviewed retrospectively. There were 210 (48.4%) female and 224 (51.6%) male patients. The average age of the patients at the surgery was 63.9 (± 12.0) years and the average follow-up period was 2.6 years [0.5, 6.5]. At the final follow-up, there was no loosening or cup failure. There were 2 infections, 1 dislocation and 1 liner fracture, resulting in revision hip surgery. Average Harris hip score improved from 53.9 preoperatively to 91.4 postoperatively. The survivorship of Regenerex Ring Loc+ cup and the low complication rate is comparable with previous studies using other 3-D porous metal prostheses. Although this short-term outcome from the institute is very encouraging, a longer follow-up study is required.
منابع مشابه
Excellent results of primary THA using a highly porous titanium cup.
Cementless acetabular cups for primary total hip arthroplasty have had excellent results, with failure rates typically less than 5% at up to 10-year follow-up. Tritanium is a 3-dimensional metal interface that has been used for porous biological fixation. The purpose of this study was to review the clinical and radiographic results of the use of Tritanium cups (Stryker Orthopaedics, Mahwah, New...
متن کاملFinite Element Analysis Stress Distribution Acetabular Cup Biomaterial FINITE ELEMENT ANALYSIS OF PERI-ACETABULAR STRESS OF CEMENTED, METAL-BACKED, AND POROUS TANTALUM BACKED ACETABULAR COMPONENTS
Introduction: In contemporary THA there are two broad approaches to acetabular cup design and materials. One is an all-polyethylene design with polymethylmethacrylate (PMMA) cement. PMMA possesses a modulus of elasticity of about 2 GPa, which is between that of trabecular and subchondral bone. The second more popular approach, especially for active, younger patients, is the porous metal-backed ...
متن کاملInfluence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...
متن کاملThree-Year Outcomes of a Highly Porous Acetabular Shell in Primary Total Hip Arthroplasty.
This multicenter study evaluated survivorship, functional outcomes, complications, and radiographic outcomes for patients who underwent total hip arthroplasty using a newly developed highly porous 3-dimensional titanium implant. Excellent aseptic (99.6%) and all-cause (98%) survivorship and functional outcomes were found at 3-year follow-up. This highly porous acetabular shell holds promise in ...
متن کامل10-year results of the uncemented Allofit press-fit cup in young patients
BACKGROUND AND PURPOSE Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. METHODS We examined the clinical and radiographic resul...
متن کامل