Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma
نویسندگان
چکیده
BACKGROUND Laser speckle flowgraphy (LSFG) enables noninvasive quantification of the retinal circulation in glaucoma patients. In this study, we tested the intrasession reproducibility of LSFG-NAVI, a modified LSFG technique. METHODS Sixty-five eyes from 33 subjects (male (M):female (F) = 17:16) with a mean age of 49.4 ± 11.2 years were examined in this study. Two parameters indicating reproducibility - the coefficient of variation (COV) and the intraclass correlation coefficient (ICC) - were analyzed three times on the same day that mean blur rate (MBR) was measured using LSFG-NAVI. The sites analyzed were the retinal artery and vein, the optic disk, and the choroid. Following classification according to the Glaucoma Hemifield Test (GHT; SITA-Standard 30-2 program), the COV and ICC were examined in patients with (GHT+; 38 eyes, M:F = 20:18, average age 48.9 ± 12.8 years) and without (GHT-; 27 eyes, M:F = 13:14, average age 50.1 ± 8.7 years) abnormal glaucomatous visual fields. RESULTS FOR ALL SUBJECTS, THE INTRASESSION REPRODUCIBILITY OF MBR IN THE OPTIC DISK (COV: 3.4 ± 2.0; ICC: 0.95) and choroid (COV: 4.7 ± 3.4; ICC: 0.98) was excellent. The reproducibility for the retinal vein (COV: 8.4 ± 5.6, ICC: 0.90) and retinal artery (COV: 10.9 ± 9.9, ICC: 0.9) was moderate. MBRs in the optic disk had good reproducibility in both the GHT+ group (COV: 3.8 ± 2.0; ICC: 0.97) and the GHT- group (COV: 2.9 ± 2.1; ICC: 0.95). Local assessment of the optic disk in normal or glaucoma patients showed that the COVs of the quadrant optic disk areas were best in the temporal area of MBR (3.4%, 4.2%, respectively). CONCLUSION LSFG-NAVI showed favorable reproducibility in evaluation of retinal circulation of glaucoma patients, particularly in the optic disk and choroid.
منابع مشابه
Retinal blood flow levels measured by laser speckle flowgraphy in patients who received intravitreal bevacizumab injection for macular edema secondary to central retinal vein occlusion.
PURPOSE To report retinal blood flow levels measured by Laser speckle flowgraphy in three patients after they received an intravitreal bevacizumab injection (IVB) for macular edema secondary to central retinal vein occlusion (CRVO). METHODS Three patients (3 eyes) being treated with IVB (1.25 mg/0.05 mL) for secondary macular edema of CRVO were examined. Laser speckle flowgraphy analyses of t...
متن کاملRelationships among Ocular Blood Flow Shown by Laser Speckle Flowgraphy, Retinal Arteriosclerotic Change, and Chorioretinal Circulation Time Obtained by Fluorescein Angiography
Purpose. To determine the correlations among the mean blur rate (MBR) in the optic nerve head (ONH) shown by laser speckle flowgraphy (LSFG), retinal arteriosclerosis, and the circulation time obtained by fluorescein angiography (FA). Method. We evaluated 118 patients and assessed their time of choroidal flush, arm-to-retina time, and early and late phases of retinal circulation time (RT: sec) ...
متن کاملReproducibility of Neonate Ocular Circulation Measurements Using Laser Speckle Flowgraphy
Measuring the ocular blood flow in neonates may clarify the relationships between eye diseases and ocular circulation abnormalities. However, no method for noninvasively measuring ocular circulation in neonates is established. We used laser speckle flowgraphy (LSFG) modified for neonates to measure their ocular circulation and investigated whether this method is reproducible. During their norma...
متن کاملDiurnal variation of pulse waveform parameters determined by laser speckle flowgraphy on the optic nerve head in healthy subjects
To investigate the diurnal variation of the pulse waveform parameters determined by laser speckle flowgraphy (LSFG) on the optic nerve head (ONH) in healthy subjects.This prospective cross sectional study was conducted at Nagoya University Hospital. We studied 13 healthy volunteers whose mean age was 33.5 ± 7.6 years. Eight pulse waveform parameters on the ONH were determined by LSFG (LSFG-NAVI...
متن کاملReal-time blood velocity measurements in human retinal vein using the laser speckle phenomenon.
PURPOSE To measure the in vivo blood velocity in human retinal veins using a laser speckle system. METHODS The system consists of a fundus camera, a diode laser, an image sensor, and a personal computer system. The fundus area, including a target retinal vein, is illuminated with a diode laser through a fundus camera and the laser speckle pattern is imaged onto the area sensor. From the time ...
متن کامل