Modified Perfluorocarbon Tracer Method for Measuring Effective Multizone Air Exchange Rates
نویسندگان
چکیده
A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this procedure, a low-cost, easy-to-use perfluorocarbon tracer (PFT) doser with a stable dosing rate was developed by using double glass vials, a needle, a polyethylene-sintered filter, and a diffusion tube. Carbon molecular sieve cartridges and carbon disulfide (CS₂) were used for passive sampling and extraction of the tracer gas, respectively. Recovery efficiencies, sampling rates, and lower detection limits for 24-h sampling of hexafluorobenzene, octafluorotoluene, and perfluoroallylbenzene were 40% ± 3%, 72% ± 5%, and 84% ± 6%; 10.5 ± 1.1, 14.4 ± 1.4, and 12.2 ± 0.49 mL min⁻¹; and 0.20, 0.17, and 0.26 μg m⁻³, respectively.
منابع مشابه
Urban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers
People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and...
متن کاملEstimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.
UNLABELLED Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon ...
متن کاملSources and migration of volatile organic compounds in mixed-use buildings.
UNLABELLED We examined concentrations and migration of volatile organic compounds (VOCs) in ten mixed-use buildings in southeast Michigan, USA. In an office and work zone in each building, air exchange rates (AERs) were measured using perfluorocarbon tracers, and over 96 VOC species were measured by GC/MS over a 7-day period. VOCs were then apportioned to sources in offices, work zones, and out...
متن کاملTheoretical and numerical studies of coupling multizone and CFD models for building air distribution simulations.
UNLABELLED Multizone network models employ several assumptions, such as uniform temperature and pressure and quiescent air inside a zone, which may lead to inaccurate results in flow calculations. These assumptions can be eliminated in the zones, where the assumptions are inappropriate, by coupling a multizone network program with a computational fluid dynamics (CFD) program. Through theoretica...
متن کاملAirflow Network Modeling in EnergyPlus
The airflow network model in EnergyPlus provides the ability to simulate multizone wind-driven airflows. The model is also able to simulate the impacts of forced air distribution systems, including supply and return air leaks. The air distribution system portion of the model is currently applicable for constant-air-volume systems. Future enhancements will include adding hybrid ventilation contr...
متن کامل