Erratum to: Fluid and structure coupling analysis of the interaction between aqueous humor and iris

نویسندگان

  • Wenjia Wang
  • Xiuqing Qian
  • Hongfang Song
  • Mindi Zhang
  • Zhicheng Liu
چکیده

© The Author(s) 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License(http:// creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium,provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, andindicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/ zero/1.0/) applies to the data made available in this article, unless otherwise stated ERRATUM Wang et al. BioMed Eng OnLine (2017) 16:22 DOI 10.1186/s12938-017-0312-4 BioMedical Engineering OnLine

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluid and structure coupling analysis of the interaction between aqueous humor and iris

BACKGROUND Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary b...

متن کامل

Modeling passive mechanical interaction between aqueous humor and iris.

Certain forms of glaucoma are associated with displacement of the iris from its normal contour. We present here a mathematical model of the coupled aqueous humor-iris system that accountsfor the contribution of aqueous humor flow and passive iris deformability to the iris contour. The aqueous humor is modeled as a Newtonian fluid, and the iris is modeled as a linear elastic solid. The resulting...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

مدل‌سازی اجزای محدود برش ماده فولادی با جت آب دارای ذرات برنده

Numerical modeling of machining processes is of significance in the parametric analysis and optimization of their performance. In this paper, a finite element-based model of abrasive waterjet (AWJ) cutting of a ductile material is presented with the help of an explicit, nonlinear finite element method. In this model, both solid-solid interaction and fluid-structure interaction are considered. T...

متن کامل

Accommodative microfluctuations and iris contour.

Mechanical interaction between aqueous humor, iris, and intraocular structures can alter the iris profile from its normal curvature. In particular, significant changes to the iris profile occur during accommodation as the anterior lens movement forces the iris into greater posterior bowing. We extended a previous mathematical model of the anterior segment and investigated the response of this c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017