Ex vivo comparison of two electronic apex locators with different scales and frequencies.

نویسندگان

  • D Hör
  • S Krusy
  • T Attin
چکیده

AIM To compare ex vivo the accuracy of two impedance quotient apex locators with different scales and frequencies of the measuring circuit. METHODOLOGY In each root of 193 extracted human teeth, electronic working length determination (ELD) was carried out with a newly constructed measuring unit. In all cases, ELD was performed using the apex locators Justy II (Hager & Werken, Duisburg, Germany) and Raypex (VDW, Munich, Germany) on the scale points (sp) 0/0.5/1 of each device. A Miller Needle reaching working length was fixed with composite. The corresponding sp and the differences to the other sp were recorded. After histological preparation of the apical region, the teeth were examined under a light microscope. The distances of the Miller Needle tips to the target intervals 'minor foramen-major foramen' and 'apical canal constriction' (apical constriction) were determined for each sp for both devices. The data were statistically analysed by a chi-square test. RESULTS Precise determination of the target interval 'minor foramen-major foramen' was successful with Raypex 4 in 94.8% (sp 1), 90.7% (sp 0.5) and 72.5% (sp 0) of cases and with Justy II in 59.6% (sp 1), 92.2% (sp 0.5) and 68% (sp 0) of cases. No measurement carried out by Raypex 4 and by Justy II on sp 1 was beyond the major apical foramen. However, on sp 0.5, there were eight measurements for Raypex 4 and four measurements for Justy II beyond the major apical foramen. Overinstrumentation was also recorded for sp 0 in 49 specimens (Raypex 4) and 59 specimens (JustyII). The major apical constriction was met exactly by Raypex 4 in 50.7% (sp 1), 14% (sp 0.5) and 5.2% (sp 0) of cases and by Justy II in 32.1% (sp 1), 23.8% (sp 0.5) and 4.1% (sp 0) of cases. The differences between the determination made with the sp suggested by the manufacturers for Raypex 4 (sp 1) and Justy II (sp 0.5) were not significant (P > 0.05) for the target interval 'minor foramen-major foramen' and significant (P <or= 0.05) for the apical constriction. The differences between the sp of each device were significant (P <or= 0.05) for both target intervals. CONCLUSIONS It is possible to determine the region between the minor and major apical foramen with electronic apex locators ex vivo. The best results were obtained using the sp advised by the manufacturers. Raypex 4 gave the best results on sp one without any measurement beyond the apical foramen. Use of ELD does not result in precise determination of the apical constriction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...

متن کامل

Evaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study

Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex&reg;6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...

متن کامل

Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.

AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...

متن کامل

ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)

Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...

متن کامل

A comparison between two electronic apex locators: an ex vivo investigation.

AIM To compare ex vivo the performance of the Apex Finder and the Root ZX apex locators, with and without irrigant, in canals having different diameters. METHODOLOGY Sixty canals in 60 teeth were prepared using stainless steel hand files and 0.04 taper NiTi rotary instruments. During preparation the narrowest diameter of the canal was transported to the apical root surface. The canals were ir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 2005