White-to-white corneal diameter: normal values in healthy Iranian population obtained with the Orbscan II.
نویسندگان
چکیده
AIM To determine the normative values of white-to-white corneal diameter with Orbscan II Topography System and to compare right and left eyes data in the normal young population. METHODS A total of 1001 healthy participants aged 18-45y participated in this observational cross-sectional study. The study population consisted of 616 female and 385 male subjects. The corneal diameter was measured with the Orbscan II. The differences between genders, between right and left eyes and age-related changes were evaluated. Statistical analyses were performed using Student's t-test. RESULTS The average white-to-white distance in our study population was recorded as 11.65±0.36 mm (median: 11.60 mm, mode: 11.70 mm, minimum: 10.50 mm and maximum: 13.60 mm). The white-to-white distance was 11.60±0.35 mm in males and 11.71±0.36 mm in females which was statistically different between genders (P<0.01). However, white-to-white distance was not statistically different between right and left eyes. In addition, this parameter decreased with increasing age. Considering 95% confidence interval, corneal diameter less than 10.93 mm and greater than 12.34 mm would be considered as microcornea and megalocornea, respectively based on this study population, using the Orbscan II topography. CONCLUSION Detailed description and analysis of corneal diameter with Orbscan demonstrate that the obtained average value of horizontal white-to-white is higher in male than female and decreases slightly with increasing age. Our data also suggests the cut off values for definition of microcornea and megalocornea, which can be employed with this population.
منابع مشابه
Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients
BACKGROUND The purpose of this study was to compare corneal power and horizontal corneal diameter (white-to-white [WTW] distance) readings obtained by the Orbscan II topographer and the iTrace aberrometer. METHODS Keratometry readings in the flat (Kf) and steep (Ks) meridians and WTW distance were measured with the Orbscan II and iTrace systems in 100 myopic patients. Statistical evaluation w...
متن کاملAngle Kappa Measurements: Normal Values in Healthy Iranian Population Obtained With the Orbscan II
BACKGROUND The angle kappa is important in proper centration of corneal ablation in keratorefractive surgery. Orbscan II device is widely used preoperatively in photoablation surgeries and can be used to measure the angle kappa. OBJECTIVES This study aimed to determine the mean angle kappa and its intercepts in healthy young Iranian adults. PATIENTS AND METHODS In this cross-sectional study...
متن کاملاندازهگیری قطر افقی قرنیه نوزادان ایرانی
Introduction : Horizontal corneal diameter is one of the diagnostic factors in some ophthalmic diseases. At present American Newborn horizontal corneal diameter is considered as our normal value in Iranian ones, while it may be quite different in Iranian newborns. Early diagnosis is critical in some ophthalmic diseases such as congenital glaucoma and awareness of normal corneal diameter is es...
متن کاملCentral and Peripheral Corneal Thickness Measurement in Normal and Keratoconic Eyes Using Three Corneal Pachymeters
PURPOSE To assess the agreement among ultrasonic pachymetry, the Galilei dual Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal thickness (CCT and PCT) measurement in normal and keratoconic eyes. METHODS In this prospective study, CCT and PCT were measured in 88 eyes of 88 refractive surgery candidates and 128 eyes of 69 keratoconic patients with ul...
متن کاملMeasurement of angle kappa with synoptophore and Orbscan II in a normal population.
PURPOSE To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. METHODS Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014