Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm.
نویسندگان
چکیده
BACKGROUND Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and morphology of reconstructed unipolar electrograms compared with contact unipolar electrograms from the same endocardial site. METHODS AND RESULTS The MEA was deployed in the left ventricles of 13 patients (end-diastolic diameters, 61.7+/-8.4 mm [mean+/-SD]). We recorded contact electrograms at 76 points equatorial and 32 points nonequatorial to the MEA during sinus rhythm using a catheter-locator signal to record direction and distance from the MEA. Morphology (cross-correlation) and timing of maximum -dV/dt of contact and reconstructed electrograms were compared at different distances from the MEA center to endocardium (M-E) and from the MEA equatorial plane. For equatorial data, the M-E was 32.12+/-12.12 mm. The timing of reconstructed with respect to contact electrograms was -1.94+/-7.12 ms for M-E <34 mm and -14.16+/-19.29 ms at M-E >34 mm (P<0.001). Cross-correlation of electrograms was 0.87+/-0.12 (95% CI, 0.84 to 0.91) and 0.76+/-0.18 (95% CI, 0.69 to 0.83) for M-E <34 mm and >34 mm, respectively. Nonequatorial points were 32.33+/-10.81 mm (range, 16.9 to 55.6 mm) from the MEA equatorial plane; electrogram timing difference was -8.97+/-15.75 ms and was unrelated to this distance from the equator. CONCLUSIONS This noncontact mapping system accurately reconstructs endocardial unipolar electrograms from the human left ventricle. At M-E distances >34 mm, timing accuracy of reconstruction decreases.
منابع مشابه
Comparison of noncontact and electroanatomic mapping to identify scar and arrhythmia late after the Fontan procedure.
BACKGROUND The right atrium late after the Fontan procedure is characterized by multiple complex arrhythmia circuits. We performed simultaneous electroanatomic and noncontact mapping to assess the accuracy of both systems to identify scar and arrhythmia. METHODS AND RESULTS Mapping was performed in 26 patients aged 26.8+/-8.9 years, 18.7+/-4.4 years after Fontan surgery. The area and site of ...
متن کاملMapping of atrial activation with a noncontact, multielectrode catheter in dogs.
BACKGROUND Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. METHODS AND RESULTS The mapping system consists of a 9F multielectrode-arr...
متن کاملThree-dimensional electrophysiological imaging of the intact canine left ventricle using a noncontact multielectrode cavitary probe: study of sinus, paced, and spontaneous premature beats.
BACKGROUND The feasibility of measuring cavitary electrograms using a noncontact probe and reconstructing endocardial surface electrograms and activation sequences during paced beats was previously demonstrated in the isolated canine left ventricle (LV). The objective of the present study was to develop and test a high-resolution, three-dimensional, endocardial electrophysiological imaging tech...
متن کاملGlobal dynamic coupling of activation and repolarization in the human ventricle.
BACKGROUND The ability to determine spatial and dynamic changes in ventricular repolarization may help to understand arrhythmogenic mechanisms in humans. We hypothesized that noncontact mapping could be used to investigate global activation-repolarization coupling in the human ventricle during steady state and premature extrastimulation. METHODS AND RESULTS Activation-recovery intervals (ARIs...
متن کاملThe value of catheter mapping during sinus rhythm to localize site of origin of ventricular tachycardia.
We assessed the value of endocardial catheter mapping in 52 patients in sinus rhythm and with 102 morphologically distinct ventricular tachycardias. The local bipolar electrograms from various regions of the left ventricle were assessed and quantitatively classified with respect to the characteristics of amplitude and duration. With the use of this assessment we found that electrograms from the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 98 9 شماره
صفحات -
تاریخ انتشار 1998