Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography. II. Instrument and results.
نویسندگان
چکیده
We describe an instrument for measuring the magnitude of birefringence of tomographic images and the principal directions of axes that use thermal-light polarization-sensitive optical coherence tomography. The instrument permits full-field measurements with an axial resolution of 1.5 microm and a transverse resolution limited by diffraction. We obtained a sensitivity of 84 dB, limited by shot noise, when we integrated the signal for 1 s. We verified the validity of the measurement by measuring the birefringence of a variable phase shifter. We present typical results obtained with optical samples.
منابع مشابه
Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography. I. Theory.
A method for measuring birefringence by use of thermal-light polarization-sensitive optical coherence tomography is presented. The use of thermal light brings to polarization-sensitive optical coherence tomography a resolution in the micrometer range in three dimensions. The instrument is based on a Linnik interference microscope and makes use of achromatic quarter-wave plates. A mathematical r...
متن کاملSpectroscopic polarization-sensitive full-field optical coherence microscopy
Full-field optical coherence tomography (FF-OCT) is a recent optical imaging technology based on low-coherence interference microscopy for imaging of semi-transparent samples with ~1 μm spatial resolution. FF-OCT produces en-face tomographic images obtained by arithmetic combination of interferometric images acquired by an array camera. In this paper, we demonstrate a unique multimodal FF-OCT s...
متن کاملImaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography.
Polarization Sensitive Optical Coherence Tomography (PS- OCT) was used to image the reduction of birefringence in biological tissue due to thermal damage. Through simultaneous detection of the amplitude of signal fringes in orthogonal polarization states formed by interference of light backscattered from turbid media and a mirror in the reference arm of a Michelson interferometer, changes in th...
متن کاملDepth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography.
Conventional polarization-sensitive optical coherence tomography (PS-OCT) can provide depth-resolved Stokes parameter measurements of light reflected from turbid media. A new algorithm that takes into account changes in the optical axis is introduced to provide depth-resolved birefringence and differential optical axis orientation images by use of fiber-based PS-OCT. Quaternion, a convenient ma...
متن کاملBirefringence measurement of the retinal nerve fiber layer by swept source polarization sensitive optical coherence tomography
A Swept Source Polarization-Sensitive Optical Coherence Tomography (SS-PS-OCT) instrument has been designed, constructed, and verified to provide high sensitivity depth-resolved birefringence and phase retardation measurements of the retinal nerve fiber layer. The swept-source laser had a center wavelength of 1059 nm, a full-width-half-max spectral bandwidth of 58 nm and an A-line scan rate of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 42 19 شماره
صفحات -
تاریخ انتشار 2003