Reactive Power Requirements of Grid Connected Induction Generator in a Weak Grid

نویسنده

  • K. S. SANDHU
چکیده

: Induction generators are gaining the popularity due to its simplicity and no synchronization problem. However the major drawback of this machine is its additional reactive burden on the system, where it is connected. In this paper an attempt is made to explore the performance of a grid connected induction generator (GCIG) due to weak grid conditions i.e. voltage and frequency fluctuations. Iterative model developed by the authors is used to predict the reactive burden of the generator due to voltage and frequency fluctuations. The comparison between experimental and simulated results proves the validity of technique proposed. Further proposed modeling is also used to include the effects of saturation. Key-Words-: Grid connected induction generator, Iterative technique, Magnetizing reactance, Saturation, Weak grid Nomenclature E1=Air gap voltage per phase fs=System frequency I1 = Stator current per phase I2= Rotor current per phase Im= Magnetizing current per phase pf = power factor Pfw = Friction and windage losses. Pg = Air gap power. Pin = Input Power. Pm = Mechanical Power. Pout = Output power. Prcu = Rotor copper losses. Pscore = Stator core losses. Pscu = stator copper losses. R1 = Stator resistance per phase R2= Rotor resistance per phase referred to stator s=Operating Slip V1=Rated terminal voltage per phase or grid voltage X1= Stator leakage reactance per phase X2= Rotor leakage reactance per phase referred to stator Xm= Saturated magnetizing reactance per phase Xmu=Unsaturated magnetizing reactance per phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

Model Predictive Control of a BCDFIG With Active and Reactive Power Control Capability for Grid-Connected Applications

Recently, Brushless Cascaded Doubly Fed Induction Generator (BCDFIG) has been considered as an attractive choice for grid-connected applications due to its high controllability and reliability. In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) method with active and reactive power control capability in grid-connected mode is proposed for controlling the BCDFIG in a way that...

متن کامل

Optimal Operation of Doubly-fed Induction Generator used in a Grid-Connected Wind Power System

In this paper, a wind power system based on a doubly-fed induction generator (DFIG) is modeled and simulated. To guarantee high-performance control of the powers injected into the grid by the wind turbine, five intelligent super-twisting sliding mode controllers (STSMC) are used to eliminate the active power and current ripples of the DFIG. The STSMC controller is a high-order sliding mode cont...

متن کامل

Reactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions

This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive ...

متن کامل

Doubly Fed Induction Generator and Conventional Synchronous Generator Based Power Plants: Operation during Grid Fault

The use of doubly fed induction generator in wind power plants has result in new necessities to maintain a reliable operation of the network. The tendency of the grid codes is to require the ability from the wind power plant to keep connected during and after grid disturbance, similarly to the synchronous generators requirements. This paper analyse the behaviour of a wind power plant equipped w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008