The observation by Hafkenscheid (1) thatPhadebas Amylase Test kitswith bovine serum albumin (BSA) gave lower results than those without BSA is, as he infers, evidently caused by differences between the standard curves supplied by the manufacturer. We found rather better agreement for plasma assays between the oldand new-formulation tablets (2). However, we routinely check the calibration curve for each lot of tablets against the stated values of Phadebas Reference Serum and Phadebas ACR (high amylase) serum. If there is a small discrepancy between our calibration line thus derived and that supplied by Pharmacia, we use our own line when it has been checked and we are satisfied that it is correct for our conditions. We have previously discussed this point (3). In our comparison of the old and new tablets (2), we made a slight alteration to the calibration linefortheoldtablets, but found it to be unnecessary for those with BSA. This had the effect of slightly lowering the results with the old tablets. It would be interesting to know whether Hafkenscheid has any assay results for the Phadebas control sera by the two methods. In our opinion, it would be wrong to introduce a new reference range for the tablets with BSA on the basis of the evidence now available. The discrepancy could just as easily have resulted from a faulty calibration line fr the old batch of tablets.
منابع مشابه
Differences in vitamin B12 results as measured with boil and no-boil kits.
on 60 sera and a linear regression equation (least squares method) ofy = 0.71x 20.66. With the Cobas Bio and 47 other sara, the regression equation was y = 0.57x + 6.37 (r = 0.96). The Boehringer method is particularly suitable for batch processing in laboratories receiving large numbers of samples because ofthe time and cost advantage [assay time 20 mm for 30 tests on the ABA 100, reagent cost...
متن کاملKinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.
We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (C...
متن کاملA normal paediatric amylase range.
A normal paediatric range of plasma alpha-amylase activity was determined using the Phadebas blue starch method. The range for children over one year was 98--405 IU/l. Plasma amylase activity increased throughout infancy. Mature levels of activity were observed in some children by age 2 months and in most of them by 9 months.
متن کاملEvaluation of amylase testing as a tool for saliva screening of crime scene trace swabs.
Amylase testing has been used as a presumptive test for crime scene saliva for over three decades, mainly to locate saliva stains on surfaces. We have developed a saliva screening application for crime scene trace swabs, utilising an amylase sensitive paper (Phadebas(®) Forensic Press test). Positive results were obtained for all tested dried saliva stains (0.5-32 μL) with high or intermediate ...
متن کاملAmylase levels in semen and saliva stains.
Amylase levels were determined for 148 semen samples and 20 saliva samples as well as for their corresponding stains. The effect of aging on the detectability of amylase activity in these stains was also investigated. The Phadebas amylase test was used for the quantitative assay of amylase. High levels of amylase in fluid saliva resulted in high levels being detected in saliva stains. Lower lev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 5 شماره
صفحات -
تاریخ انتشار 1979