Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography.
نویسندگان
چکیده
SUBJECT OBJECTIVE To assess the accuracy of a portable monitoring device based on peripheral arterial tonometry to diagnose obstructive sleep apnea (OSA). To propose a new standard for limited-channel device validation using synchronized polysomnography (PSG) home recordings and a population-based cohort. DESIGN Single-night, unattended PSG and Watch_PAT 100 (WP_100). SETTING Home environment. PARTICIPANTS Ninety-eight subjects (55 men; age, 60 +/- 7 year; body mass index, 28 +/- 4 kg/m2) consecutively recruited from the Skaraborg Hypertension and Diabetes Project. MEASUREMENTS AND RESULTS The WP_100 records peripheral arterial tone, heart rate, oxygen saturation and actigraphy for automatic analysis of respiratory disturbance index (RDI), apnea-hypopnea index (AHI), oxygen desaturation index (ODI), and sleep-wake state. The accuracy of WP_100 in RDI, AHI, ODI, and sleep-wake detection was assessed by comparison with data from simultaneous PSG recordings. The mean PSG-AHI in this population was 25.5 +/- 22.9 events per hour. The WP_100 RDI, AHI, and ODI correlated closely (0.88, 0.90, and 0.92; p < .0001, respectively) with the corresponding indexes obtained by PSG. The areas under the curve for the receiver-operator characteristic curves for WP_100 AHI and RDI were 0.93 and 0.90 for the PSG-AHI and RDI thresholds 10 and 20 (p < .0001, respectively). The agreement of the sleep-wake assessment based on 30-second bins between the 2 systems was 82 +/- 7%. CONCLUSIONS The WP_100 was reasonably accurate for unattended home diagnosis of OSA in a population sample not preselected for OSA symptoms. The current design, including simultaneous home PSG recordings in population-based cohorts, is proposed as a reasonable validation standard for assessment of simplified recording tools for OSA diagnosis.
منابع مشابه
Comparison of home oximetry monitoring with laboratory polysomnography in children.
STUDY OBJECTIVES To measure the accuracy and reliability of a portable home oximetry monitor with an automated analysis for the diagnosis of obstructive sleep apnea (OSA) in children. DESIGN Prospective cohort study. SETTING Alberta Lung Association Sleep Center, Alberta Children's Hospital Sleep Clinic. STUDY SUBJECTS Consecutive, otherwise healthy children, aged 4 to 18 years, presentin...
متن کاملClinical validation of the Bedbugg in detection of obstructive sleep apnea.
OBJECTIVE To validate the accuracy of the Bedbugg, a new home monitoring device for diagnosis of obstructive sleep apnea. STUDY DESIGN AND SETTING Simultaneous sleep monitoring was performed by formal polysomnography and by Bedbugg. Monitoring was performed in a university sleep center in 42 subjects who had previously been scheduled for polysomnography. RESULTS The correlation for the apne...
متن کاملA multisite randomized trial of portable sleep studies and positive airway pressure autotitration versus laboratory-based polysomnography for the diagnosis and treatment of obstructive sleep apnea: the HomePAP study.
STUDY OBJECTIVES To test the utility of an integrated clinical pathway for obstructive sleep apnea (OSA) diagnosis and continuous positive airway pressure (CPAP) treatment using portable monitoring devices. DESIGN Randomized, open-label, parallel group, unblinded, multicenter clinical trial comparing home-based, unattended portable monitoring for diagnosis and autotitrating CPAP (autoPAP) com...
متن کاملUse of a portable monitoring device (Somnocheck Micro) for the investigation and diagnosis of obstructive sleep apnoea in comparison with polysomnography
OBJECTIVE Polysomnography (PSG) remains the gold standard for the diagnosis of obstructive sleep apnoea syndrome (OSAS). While PSG is essential for OSAS, this technique is not suitable for epidemiological investigation due to its high cost. This study aimed to compare a portable monitoring device with PSG for the measurement of parameters related to the diagnosis of OSAS in rural areas. METHO...
متن کامل國 立 交 通 大 學 the Development of Wireless Polysomnography System for Sleep Monitoring at Home 無線多重生理狀態監控系統-應用於居家睡眠監控 the Development of Wireless Polysomnography System for Sleep Monitoring at Home 無線多重生理狀態監控系統-應用於居家睡眠監控
The polysomnography (PSG) is considered as the gold standard for the diagnosis of Obstructive Sleep Apnea (OSA). The examination of OSA requires an overnight sleep experiment in a laboratory. However, due to the limitation for number of labs and beds, patients often have to wait for a long time before being diagnosed and eventually treated. In addition, the unfamiliar environment and restricted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Sleep
دوره 29 3 شماره
صفحات -
تاریخ انتشار 2006