Expanding the versatility of cardiac PET/CT: feasibility of delayed contrast enhancement CT for infarct detection in a porcine model.

نویسندگان

  • Andrew Holz
  • Riikka Lautamäki
  • Tetsuo Sasano
  • Jennifer Merrill
  • Stephan G Nekolla
  • Albert C Lardo
  • Frank M Bengel
چکیده

UNLABELLED It has recently been suggested that, similar to MRI, CT can be used to detect infarcts at high resolution by delayed myocardial contrast enhancement. In cardiac PET/CT, this ability to detect infarcts may increase the versatility and integrative potential of PET and CT study components. We sought to determine the feasibility of delayed CT-enhancement in the PET/CT environment and compared it with PET-defined rest perfusion for the measurement of infarct size. METHODS Experimental myocardial infarction was induced in 10 young farm pigs by occlusion and reperfusion of the left anterior descending coronary artery. After 4-6 wk, the animals underwent 64-slice PET/CT. Rest perfusion was measured by 13N-ammonia PET. Then, 120 mL of contrast were injected, and retrospectively gated helical CT was performed for angiography and after 1.5-, 5-, 10-, and 15-min delays. Two days later, 6 pigs again underwent contrast-enhanced CT, using a low-radiation-dose approach (prospective gating and thicker slices as used for clinical calcium scoring) and the same delay times. Polar maps of PET perfusion and CT myocardial enhancement were created for further analysis. RESULTS CT Hounsfield units (HUs) in the infarct area started to exceed those of arterial blood at 5-10 min after contrast injection, and the ratios of infarcted myocardium to remote myocardium and of infarcted myocardium to blood plateaued at around 1.9 and 1.2 between 10 and 15 min. Excellent agreement between high- and low-dose CT acquisitions (R=0.87, P<0.001) was demonstrated. At 10 min, CT infarct size (area with HU>3.5 SDs from remote) was 30%+/-8% of the left ventricle, using the low-dose approach. The PET perfusion defect size (area with uptake<60% of the left ventricular maximum) was comparable at 31%+/-8% of the left ventricle (range, 17%-44%). Using a 16-segment myocardial model, we showed an excellent inverse relationship between regional ammonia retention and contrast enhancement (R=-0.93, P<0.001). CONCLUSION In our animal model, infarct size can be measured accurately and reproducibly using cardiac PET/CT with delayed CT-enhancement. For measurement, a low-dose, prospectively gated acquisition was comparable to higher-dose spiral CT. These results provide a rationale for further clinical work to explore whether delayed CT-enhancement can improve the accuracy of myocardial viability assessment, substitute for rest studies in perfusion imaging, or improve localization of PET-derived molecular signals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

Rare case of squamous cell carcinoma of buccal mucosa metastasizing to interventricular septum in a young adult detected by 18F-FDG PET-CT

Metastatic tumors to the heart unlike primary cardiac tumors are not rare. Despite its frequency, cardiac metastasis is commonly detected only during autopsy as the symptoms of disseminated metastasis prevail over symptoms caused by cardiac metastasis and hence is overlooked most of the time. Tumors more commonly found metastasizing to the heart are malignancies of lung, breast, esophagus, lymp...

متن کامل

Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT), magnetic resonance imaging (MRI), and dual-time-point 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2009