Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Our aim was to evaluate whether increasing iodine concentration, at a constant total iodine dose, resulted in better brain tissue opacification in patients with acute stroke symptoms during their evaluation by first-pass CT perfusion (CTP). MATERIALS AND METHODS One hundred two patients presenting to the emergency department within 3 hours of onset of acute stroke symptoms underwent CTP scanning. Three different concentrations of iodinated nonionic contrast material were used (300, 350, or 400 mg/mL). Total iodine dose (15 g) and injection rate (7 mL/s) were kept constant. There were 25, 53, and 19 patients in the different concentration groups, respectively; 5 patients were excluded due to uncorrectable motion artifacts. CTP scanning was performed at the level of the putamen, and data were analyzed by determining peak opacification for normal gray and white matter, arterial input, and venous output. Mean and SD values were calculated, and 3 concentration groups, stratified by region-of-interest location, were compared by using a single-tailed unpaired t test. RESULTS Monotonic increasing peak opacification was observed in all region-of-interest locations. Statistically significant differences were observed between the 300 and 350 mg/mL, 300 and 400 mg/mL, as well as the 350 and 400 mg/mL groups (P<.01) in white matter, gray matter, and the arterial input. Statistical significance was seen in the venous output group between the 300 and 400 mg/mL (P<.005) and 350 and 400 mg/mL (P<.007) groups, but not between the 300 and 350 mg/mL (P=.2) groups. CONCLUSION Increasing contrast concentration improves peak opacification of tissue, suggesting that CTP evaluation of patients with acute stroke is better performed with the highest available concentration contrast agent.
منابع مشابه
Mouse myocardial first-pass perfusion imaging
Figure 3: (left) First-pass perfusion images in a mouse with myocardial infarction. (right) Signal intensity-time curves extracted from three different ROIs. At time ‘A’, a lower rate of contrast agent uptake was seen in the infarcted myocardium, followed by a period of delayed-enhancement ‘B’. Figure 2: (top) Typical first-pass perfusion images in a healthy mouse. (bottom) Signal intensity-tim...
متن کاملAre Dynamic First-pass Enhancement Properties of Gadoxetic acid (Gd-EOB-DTPA) Comparable to Gadopentetate dimeglumine (Gd-DTPA) in Hepatocellular Carcinoma (HCC)?
Introduction: Gadoxetic acid (Gd-EOB-DTPA) is a recently approved contrast agent which has hybrid properties of hepatocyte specific and extracellular, enabling the evaluation of both tissue perfusion and hepatobiliary excretion. Dynamic first-pass enhancement pattern has been the key word for HCC. However, we have been familiar with that using standard Gd-chelate agents. The purpose of our stud...
متن کاملFirst-pass entry of nonionic contrast agent into the myocardial extravascular space. Effects on radiographic estimates of transit time and blood volume.
BACKGROUND Almost all x-ray-based techniques intended to assess regional myocardial perfusion from myocardial concentration-time curves following the administration of soluble contrast agents assume that these agents behave as intravascular indicators and can therefore provide measurements of intravascular transit time and intramyocardial blood volume. METHODS AND RESULTS We tested this assum...
متن کاملA Parametric Model for Quantitative Analysis of Contrast-Enhanced First-Pass MR Myocardial Perfusion that Accounts for Gd-DTPA Interstitial Loading
Introduction: Quantitative analysis of contrast-enhanced first-pass MR myocardial perfusion is useful for the detection of coronary artery disease. Myocardial blood flow (MBF) estimated from both arterial and myocardial time signal intensity curves provides more linear dynamic range for the assessment of myocardial ischemia than using semi-quantitative indices such as upslope and contrast enhan...
متن کامل3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses.
PURPOSE To compare myocardial enhancement during first-pass myocardial perfusion imaging at 3.0 Tesla (T) and 1.5T. MATERIALS AND METHODS First-pass myocardial perfusion imaging was performed on twelve normal subjects at 3T and 1.5T using an interleaved notched saturation recovery gradient echo pulse sequence. Subjects received either 0.10 mmol/kg for both scans (group 1), 0.075 mmol/kg for b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 7 شماره
صفحات -
تاریخ انتشار 2007