Modified MicroSecure Vitrification: A Safe, Simple and Highly Effective Cryopreservation Procedure for Human Blastocysts

نویسندگان

  • Mitchel C. Schiewe
  • Shane Zozula
  • Nancy Nugent
  • Kelley Waggoner
  • Jessica Borba
  • Lisa Gamboa
  • John B. Whitney
چکیده

Clinical embryo vitrification evolved with the development of unique vitrification devices in the 21st century and with the misconception that ultra-rapid cooling in an "open" system (i.e., direct LN2 contact) was a necessity to optimize vitrification success. The dogma surrounding the importance of cooling rates led to unsafe practices subject to technical variation and to the creation of vitrification devices that disregarded important quality-control factors (e.g., ease of use, repeatability, reliability, labeling security, and storage safety). Understanding the quality-control flaws of other devices allowed for the development of a safe, secure, repeatable, and reliable µS-VTF method aimed to minimize intra- and inter-technician variation. Equally important, it combined the availability of two existing FDA-compliant devices: 1) a 0.3-mL ionomeric resin embryo straw with internalized, dual-colored, tamper-proof labeling with repeatable weld seal potential; and 2) shortened, commonly-used, 300-µm ID sterile flexipettes to directly load the embryo(s) in order to create a highly-effective global vitrification device. Like other aseptic, closed vitrification systems (e.g., High Security Vitrification (HSV), Rapid-i, and VitriSafe) effectively used in reproductive medicine, microSecure Vitrification (µS-VTF) has proven that it can achieve high post-warming survival and pregnancy outcomes with its attention to simplicity, and reduced technical variation. Although the 0.3-mL embryo straw containing an internal hydrophobic plug was commercially replaced with a standard semen straw possessing cotton-polyvinyl pyrrolidone (PVP) plugs, it maintained its ionomeric resin composition to ensure weld sealing. However, the cotton plugs can wick out the fluid-embryo contents of the flexipettes upon contact. A modified µS-VTF method was adapted to include an additional internal weld seal before the plug on the device loading side. The added technical step to the µS-VTF procedure has not affected its successful application, as high survival rates (> 95%) and pregnancy rates continue today.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of open and closed methods for vitrification of human embryos and the elimination of potential contamination.

Survival and development of human embryos was compared following slow cooling versus vitrification involving more than 13,000 vitrified embryos. In addition, the efficacy of an open system, the Cryotop, and a closed vitrification system, the CryoTip(trade mark), were compared using human blastocysts. One hundred percent of vitrified human pronuclear stage embryos survived and 52% developed to b...

متن کامل

Neonatal outcomes after the transfer of vitrified blastocysts: closed versus open vitrification system

BACKGROUND Increasing evidence indicates that closed vitrification has been successfully used in the cryopreservation of human oocytes and embryos. Little information is available regarding the neonatal outcome of closed blastocysts vitrification. The aim of this study was to evaluate the effectiveness and safety of blastocyst vitrification using a high-security closed vitrification system comp...

متن کامل

A new safe, simple and successful vitrification method for bovine and human blastocysts.

This study examined a new method for vitrification of blastocysts that is safe, simple and easy to learn and use. Current vitrification techniques have shortcomings that include the use of dimethyl sulphoxide, one of the more toxic cryoprotectants, and minute containers that are difficult to handle and are usually open to contamination. Cell handling and loading times are very short, which allo...

متن کامل

Outcome of closed blastocyst vitrification in relation to blastocyst quality: evaluation of 759 warming cycles in a single-embryo transfer policy.

BACKGROUND In order to optimize blastocyst cryopreservation, vitrification was introduced as the routine procedure instead of slow freezing. The outcome of a closed blastocyst vitrification system was evaluated in relation to the blastocyst score before cryopreservation in single embryo transfers (SETs). METHODS Supernumerary blastocysts of IVF/ICSI patients with a fresh Day 5 transfer were v...

متن کامل

Highly efficient vitrification method for cryopreservation of human oocytes.

Two experiments were performed to develop a method to cryopreserve MII human oocytes. In the first experiment, three vitrification methods were compared using bovine MII oocytes with regard to their developmental competence after cryopreservation: (i) vitrification within 0.25-ml plastic straws followed by in-straw dilution after warming (ISD method); (ii) vitrification in open-pulled straws (O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2017