The use of bioerodible polymers and 5-fluorouracil in glaucoma filtration surgery.

نویسندگان

  • D A Lee
  • K W Leong
  • W C Panek
  • C T Eng
  • B J Glasgow
چکیده

A study was performed to examine the effect of a localized and sustained delivery of 5-fluorouracil (5-FU) on the success of glaucoma filtration surgery in 18 rabbits in a prospective, randomized, double-masked and placebo-controlled fashion. A bioerodible polyanhydride composed of bis (p-carboxyphenoxy) propane and sebacic acid was used as the drug carrier. The polymer and 5-FU (20% by weight) were compressed into 3 mm diameter discs, 1 mm thick. The polymer with the 5-FU was randomized to one eye and the fellow eye received the blank polymer. The results showed that intraocular pressures (IOP) were lower in the experimental eyes during the 5th through 17th postoperative days, but eventually both experimental and control eyes returned to preoperative levels. Filtration blebs lasted longer in experimental eyes when compared to control eyes. Implant disappearance occurred after IOP elevations and bleb failure. Eventually, the filtration surgery failed in both the experimental and control rabbit eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined treatment with bevacizumab and 5-fluorouracil attenuates the postoperative scarring response after experimental glaucoma filtration surgery.

PURPOSE This study evaluated the use of combined bevacizumab with 5-fluorouracil (5-FU) on postoperative scarring and bleb survival after experimental glaucoma filtration surgery in comparison to the agents alone. METHODS Filtration surgery was performed on 26 female New Zealand White rabbits. The rabbits were allocated to one of four treatments: 5-FU combined with bevacizumab, 5-FU alone, be...

متن کامل

Wound Healing Modulation in Glaucoma Filtration Surgery—Conventional Practices and New Perspectives

Glaucoma filtration surgery is regularly performed for the treat ment of glaucoma and trabeculectomy is often regarded as the ‘gold standard’ glaucoma operation. The biggest risk of failure of the operation is bleb scarring. The advent of anti-fibrotic agents, such as mitomycin C (MMC) and 5-fluorouracil (5FU) has vastly prolonged the longevity of the bleb, but concerns remain regarding the pot...

متن کامل

Wound modulation after filtration surgery.

Filtration surgery is the standard invasive procedure for the management of intraocular pressure in advanced glaucoma. The key to a successful outcome is to modulate the normal wound healing cascade that leads to closure of the newly created aqueous outflow pathway. Antifibrotic agents such as mitomycin C and 5-fluorouracil have been increasingly used to modulate the wound healing process and i...

متن کامل

Wound Healing Modulation in Glaucoma Filtration Surgery– Conventional Practices and New Perspectives: Antivascular Endothelial Growth Factor and Novel Agents (Part II)

Glaucoma filtration surgery is regularly performed for the treatment of glaucoma and trabeculectomy is often regarded as the 'gold standard' glaucoma operation. The biggest risk of failure of the operation is bleb scarring. The advent of antifibrotic agents, such as mitomycin C (MMC) and 5-fluorouracil (5FU) has vastly prolonged the longevity of the bleb, but concerns remain regarding the poten...

متن کامل

Wound Healing Modulation in Glaucoma Filtration Surgery-Conventional Practices and New Perspectives: The Role of Antifibrotic Agents (Part I).

Glaucoma filtration surgery is regularly performed for the treatment of glaucoma and trabeculectomy is often regarded as the 'gold standard' glaucoma operation. The biggest risk of failure of the operation is bleb scarring. The advent of anti-fibrotic agents, such as mitomycin C (MMC) and 5-fluorouracil (5FU) has vastly prolonged the longevity of the bleb, but concerns remain regarding the pote...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 29 11  شماره 

صفحات  -

تاریخ انتشار 1988